700W/ 1000VA
700W/ 1000VA
230V
Configurable for 220: 230 or 240 nominal output voltage
Less than 3%
50/60Hz +/- 3 Hz user adjustable +/- 0.1
220/240V
3:1
Double Conversion Online
Sine wave
6x IEC 320 C13
2x IEC Jumpers
Built-in Bypass
230V
50/60Hz +/- 5Hz (auto sensing)
IEC-320 C14
Range for main operations: 160 - 280V
Adjustable range for mains operation: 100 - 280V
220, 240V
Less than 7% for full load
Maintenance-free sealed Lead-Acid battery with suspended electrolyte: leakproof
1
3 hours
RBC31
1
APC Smart-UPS RT 1000VA RM 230V
80.4%
86.4%
88.3%
89.1%
DB-9 RS-232, SmartSlot
1
LED status display with load and battery bar-graphs and On Line
On Battery
Replace Battery
Overload and Bypass Indicators
Alarm when on battery
Distinctive low battery alarm
Overload continuous tone alarm
Optional
420 Joules
Full time multi-pole noise filtering: 0.3% IEEE surge let-through: zero clamping response time: meets UL 1449
2U
0 to 40 deg. C / 32 to 104 deg. F
0 - 95% no%
0-3000m / 0-9842.40'
-20 to 50 deg. C / -4 to 122 deg. F
0 - 95% no%
0-15000m / 0-49212.00'
50.00 dBA at 1 meter from surface of unit
324.00 BTU/hr
IP 20
C-tick, CE, EN 50091-1, EN 50091-2, EN 55022 Class A, EN 60950, EN 61000-3-2, GOST, VDE
Compliant
85 x 432 x 483mm / 3.35 x 17.01 x 19.02"
23kg / 50.71lbs
Availability
Automatic internal bypass: Supplies utility power to the connected loads in the event of a UPS power overload or fault
Scalable runtime: Allows additional run time to be quickly added as needed
Intelligent battery management: Maximizes battery performance, life and reliability through intelligent, precision charging
Hot-swappable batteries: Ensures clean, uninterrupted power to protected equipment while batteries are being replaced
Automatic restart of loads after UPS shutdown: Automatically starts up the connected equipment upon the return of utility power
Temperature-compensated battery charging Prolongs battery life by regulating the charge voltage according to battery temperature
Manageability
Network manageable: Provides remote power management of the UPS over the network
InfraStruxure Manager Compatible: Enables centralized management via the APC InfraStruxure Manager
SmartSlot Customize UPS capabilities with management cards
LED status indicators: Quickly understand unit and power status with visual indicators
Serial connectivity: Provides management of the UPS via a serial port
Adaptability
Plug-and-Play external batteries: Ensures clean, uninterrupted power to the loads when adding extra runtime to the UPS
Rack/Tower convertible: Protects the initial investment in the UPS when migrating from tower to rack-mount environment
Flash upgradeable firmware: Install maintenance releases of firmware remotely using FTP
Serviceability
User-replaceable batteries: Increases availability by allowing a trained user to perform upgrades and replacements of the batteries reducing Mean Time to Repair (MTTR)
Automatic self-test: Periodic battery self-test ensures early detection of a battery that needs to be replaced
Predicitive failure notification: Provides early-warning fault analysis ensuring proactive component replacement
Disconnected battery notification: Warns when a battery is not available to provide backup power
Audible alarms: Provides notification of changing utility power and UPS power conditions
Protection
Frequency and voltage regulation: Gives higher application availability by correcting poor frequency and voltage conditions without using the battery
Power conditioning: Protects connected loads from surges, spikes, lightning and other power disturbances
Input power factor correction: Minimizes installation costs by enabling the use of smaller generators and cabling
Generator compatible: Ensures clean, uninterrupted power to protected equipment when generator power is used
Cold-start capable: Provides temporary battery power when the utility power is out
Resettable circuit breaker: Easy recovery from overloads; no need to replace a fuse
Safety-agency approved: Ensures the product has been tested and approved to work safely with the connected service provider equipment and within the specified environment