See Options
2 Year
$219.99
3 Year
$349.99
5 Year
$689.99
Need help? Ask our experts.
Review Summary
Accidents happen. Protect your favorite Adorama products and purchase a protection plan to stay covered from accidental damage, mechanical or electrical failures, and more.
If we can’t fix it, we’ll replace it at no additional cost.
Protect your product from drops, spills, and more.
Enjoy your gear without fear. We have you covered!
When regular use of your product over time results in mechanical or electrical failure.
We will never charge you a deductible after the purchase of a plan.
Our claims process is simple & easy and our customer service team is happy to help.
Adorama Protect powered by Extend is available for purchase to customers in the United States. Not available for international or U.S. territories purchases. Plans on open box items do not cover pre-existing damage.
Adorama Protect plans are available for ABS clients. If you have any questions or require assistanse, please call 800-223-2500
Browse our FAQ
Individual input attenuators, AC Power Switch
Temp dependent speed-controlled fan (Side-in, Front-out)
Power: Switch: On, Off (Blue)
Standby: Standby, flashing (Yellow)
Protect: On, Off (Red)
Disable: On, Off (Yellow)
COM: On, for Ethernet data or Device ID (Green)
Signal level: Clip (Red); -6dB (Yellow) and -18dB, -12dB (Green)
Bridge: Per Channel Pair (Green)
Temp: Per Channel (Yellow)
Current: Per Channel: Proportional to output (Green)
4
8 Ohm: 150W
4 Ohms: 250W
(Continuous Average Power Output: Per Channel, Low Z Models, Stereo Mode, All Channels Driven)
8 Ohm: 500W (Low Z Output: Bridge Mode, All Channels Driven)
70V (Per Channel): 250W
190mA
540mA
2.85A (1/8 Power Pink Noise)
6A (1/3 Power Pink Noise)
46.7 BTU/hr (All Channels Driven)
123 BTU/hr (All Channels Driven)
341 BTU/hr (1/8 power pink noise, All Channels Driven)
378 BTU/hr(1/3 power pink noise, All Channels Driven)
20Hz-20kHz, (unweighted) +/-1dB
20k Ohms, Balanced
32dB
7.2dBu
+21dBu
80Hz (12dB/oct), 400Hz (6dB oct), OFF (25V, 70V, 100V models)
>107dB (20-20k, Unweighted)
<0.5% (SMPTE, typical)
<0.5% (THD-N, typical, 20Hz-20kHz)
>250 (8 Ohms, 1kHz)
Class D
Output Overcurrent, Main Supply Rail Overvoltage, Chassis Temperature, Inrush Limiting, Mains Fuse
Ethernet, Channel bridge switch (Low-Z only), Remote Standby, Preset Recall (4), Remote Level (8), Remote Data
Input: Euroblock
Output: Euroblock
120VAC or 240VAC +/-10% (factory set), 50-60Hz
15A Edison, 3-Prong IEC
IN through sides, OUT through front
40 to 120 degree F (4 to 49 degree C) noncondensing
TUV, CE, FCC, RoHS
19 x 3.50 x 16.84" (483 x 89 x 428mm)
23 lb (10.4kg)
NE Series Multi-Channel, Network-Enabled Power Amplifiers
Our multi-channel ne (Networked-Enabled) Series Amplifiers are uniquely designed around an energy efficient Class-D platform with a switching power supply.
Connecting and controlling an amplifier for networked systems has now been simplified with ne Amplifiers. This line offers ease of use, setup and control using standard 10/100 Ethernet protocol and Protea ne Software. No special outboard control units are needed.
Choose either the ne4250 (4-channel) or ne8250(8-channel) packages rated at 250W per channel, with separate Hi-Z and Low-Z models. ne Series Amplifiers are offered in two separate platforms-the standard network amplifier or a network amplifier with an on-board Protea DSP Processor. Each can be customized for any installation by adding your choice of AES3 inputs, mic pre inputs, CobraNet or Dante modules.
ne4250.70: Architect & Engineering Specs
The four-channel power amplifier shall deliver a minimum power of 250 Watts RMS per channel into 70V loads with all channels operating. When switched into bridged-mono mode, channels 1+2 or 3+4 of the amplifier shall deliver at least 500 Watts RMS into a 140V load. The power amplifier shall include Euroblock input connectors and Euroblock output connectors. It shall have balanced analog inputs.
The power amplifier shall have remote standby for power up, DC remote level control and contact closure preset recall. It shall have Ethernet control and monitoring of power functions, level, mute, polarity, temperature, current, and amplifier fault conditions. Frequency response shall be 20Hz to 20kHz +/-1.0dB.
Signal-to-Noise shall be greater than 105dB unweighted and SMPTE intermodulation distortion shall be less than 0.5% into an 8 Ohm load, 10dB below rated output. The front panel shall provide the status of power, standby, protect, power switch disable, signal level, bridge, over-temperature, over-current, and Ethernet communication.
The power amplifier will be capable of having factory installed AES3, CobraNet, or Dante interface options with the addition of a 4-Channel DAC card. The amplifier shall mount in a standard 19 inch rack using two spaces (3.5. high) and weigh 23 pounds (10.4kg) or less.
https://ashly.com/warranty-information
800-828-6308