See Options
2 Year
$499.99
3 Year
$649.99
5 Year
$949.99
Need help? Ask our experts.
Review Summary
Accidents happen. Protect your favorite Adorama products and purchase a protection plan to stay covered from accidental damage, mechanical or electrical failures, and more.
If we can’t fix it, we’ll replace it at no additional cost.
Protect your product from drops, spills, and more.
Enjoy your gear without fear. We have you covered!
When regular use of your product over time results in mechanical or electrical failure.
We will never charge you a deductible after the purchase of a plan.
Our claims process is simple & easy and our customer service team is happy to help.
Adorama Protect powered by Extend is available for purchase to customers in the United States. Not available for international or U.S. territories purchases. Plans on open box items do not cover pre-existing damage.
Adorama Protect plans are available for ABS clients. If you have any questions or require assistanse, please call 800-223-2500
Browse our FAQ
Individual input attenuators, AC Power Switch
Temp dependent speed-controlled fan (Side-in, Front-out)
Power: Switch: On, Off (Blue)
Standby: Standby, flashing (Yellow)
Protect: On, Off (Red)
Disable: On, Off (Yellow)
COM: On, for Ethernet data or Device ID (Green)
Signal level: Clip (Red); -6dB (Yellow) and -18dB, -12dB (Green)
Bridge: Per Channel Pair (Green)
Temp: Per Channel (Yellow)
Current: Per Channel: Proportional to output (Green)
8
8 Ohm: 150W
4 Ohms: 250W
(Continuous Average Power Output: Per Channel, Low Z Models, Stereo Mode, All Channels Driven)
8 Ohm: 500W (Low Z Output: Bridge Mode, All Channels Driven)
70V (Per Channel): 250W
290mA
565mA
5A (1/8 Power Pink Noise)
11A (1/3 Power Pink Noise)
63.8 BTU/hr (All Channels Driven)
187 BTU/hr (All Channels Driven)
700 BTU/hr (1/8 power pink noise, All Channels Driven)
775 BTU/hr(1/3 power pink noise, All Channels Driven)
20Hz-20kHz, (unweighted) +/-1dB
20k Ohms, Balanced
32dB
7.2dBu
+21dBu
80Hz (12dB/oct), 400Hz (6dB oct), OFF (25V, 70V, 100V models)
>107dB (20-20k, Unweighted)
<0.5% (SMPTE, typical)
<0.5% (THD-N, typical, 20Hz-20kHz)
>250 (8 Ohms, 1kHz)
Class D
Output Overcurrent, Main Supply Rail Overvoltage, Chassis Temperature, Inrush Limiting, Mains Fuse
Ethernet, Channel bridge switch (Low-Z only), Remote Standby, Preset Recall (4), Remote Level (8), Remote Data
Input: Euroblock
Output: Euroblock
120VAC or 240VAC +/-10% (factory set), 50-60Hz
15A Edison, 3-Prong IEC
IN through sides, OUT through front
40 to 120 degree F (4 to 49 degree C) noncondensing
TUV, CE, FCC, RoHS
Analog, Auto (Net, AES3, Analog)
-20dBu to +20dBu
infinity
0.2ms/dB to 50 ms/dB
5ms/dB to 1000ms/dB
-20dBu to +20dBu
1.2:1 to infinity
0.2 to 50ms
5ms/dB to 1000ms/dB
Peak/Average
2 available
In, Out, Attenuation, Graphical
-40dBu to +20dBu
Gentle, normal, aggressive, user-defined
0dB to +22dB
Input Level, Gain, Attenuation
1.2:1 to 10:1
-30dB to 0dB
5ms/dB to 1000ms/dB
0-6 sec
-80dBu to +20 dBu
5ms/dB to 1000ms/dB
0dB to -30dB, infinity
Yes
Input
-80dBu to +20dBu
off, 100dB to 0dB
0.2ms/dB to 50 ms/dB
5ms/dB to 1000ms/dB
Key Signal, Gate LED, Graphical
Yes
20Hz to 20kHz
0.016 to 3.995 Octave
-50dB to +12dB, off, polarity invert
4 available
Enable per channel, 0dB to infinity
0 to -50dB, Mute
.csv, .fir (Output only, 48kHz only, 2-384 Taps)
Constant Q or Proportional
0.499oct to 0.25oct
20-20kHz
-30dB to +15dB
0.016 to 3.995 Octave
20Hz-20kHz
-15dB to +15dB
20Hz-20kHz
20Hz-20kHz
3.047 to 0.267
20Hz-20kHz
92.436 to 0.267
12/18/24/48 dB/oct
12/24/48 dB/oct
Off, 20Hz-20KHz
0-21ms
0-682ms
0-10.6ms
0-341ms
-60dBu to +20dBu
1dB
Yes
Off, -50dBu to +20dBu
20Hz-12kHz
Off, -50dB to +12dB
Per channel
Yes
24 bit
32-bit floating point
48kHz, 96kHz
1.42ms
0.71ms
19 x 3.50 x 16.84" (483 x 89 x 428mm)
23 lb (10.4kg)
NE Series Multi-Channel, Network-Enabled Power Amplifiers
Our multi-channel ne (Networked-Enabled) Series Amplifiers are uniquely designed around an energy efficient Class-D platform with a switching power supply.
Connecting and controlling an amplifier for networked systems has now been simplified with ne Amplifiers. This line offers ease of use, setup and control using standard 10/100 Ethernet protocol and Protea ne Software. No special outboard control units are needed.
Choose either the ne4250 (4-channel) or ne8250(8-channel) packages rated at 250W per channel, with separate Hi-Z and Low-Z models. ne Series Amplifiers are offered in two separate platforms-the standard network amplifier or a network amplifier with an on-board Protea DSP Processor. Each can be customized for any installation by adding your choice of AES3 inputs, mic pre inputs, CobraNet or Dante modules.
ne8250.70 with DSP: Architect & Engineering Specs
The eight-channel power amplifier shall deliver a minimum power of 250 Watts RMS per channel into 70V loads with all channels operating. When switched into bridged-mono mode, channels 1+2 or 3+4 or 5+6 or 7+8 of the amplifier shall deliver at least 500 Watts RMS into a 140V load.
The power amplifier shall include Euroblock input connectors and Euroblock output connectors. It shall have balanced analog inputs. The power amplifier shall have remote standby for power up, DC remote level control and contact closure preset recall. It shall have Ethernet control and monitoring of power functions, level, mute, polarity, temperature, current, and amplifier fault conditions.
Frequency response shall be 20Hz to 20kHz +/-1.0dB. Signal-to-Noise shall be greater than 105dB unweighted and SMPTE intermodulation distortion shall be less than 0.5% into an 8 Ohm load, 10dB below rated output. The front panel shall provide the status of power, standby, protect, power switch disable, signal level, bridge, over-temperature, overcurrent, and Ethernet communication.
The power amplifier shall have an internal factory installed digital signal processing (DSP) option controlled using Protea (network-enabled) software. Each amplifier input channel shall be configured with pluggable DSP blocks to have its own dynamics control, gain functions, graphic and/or parametric EQ, Hi-pass/Lo-pass filters, time delay, metering, and test signal generator. A mixer section with assignable routing shall allow any input to drive any or all amplifier outputs.
Outputs shall have the same DSP functions as inputs, with the addition of FIR filters, and a fast, automated crossover setup. Both inputs and outputs shall copy/paste their settings to other channels, or link with one or more other channels to track their settings.
Presets shall be used to store and retrieve global parameters of an amplifier's control surface and DSP section from a file. Sub-Presets shall allow for a collection of individual DSP function parameters within and across both channels of an amplifier to be stored and recalled as a set, affecting only those parameters which have been tagged.
Up to 35 presets/sub-presets shall be stored within the amplifier, and shall be recalled in real time via Ethernet from a computer using Protea software. The power amplifier will be capable of having factory installed AES3, CobraNet, or Dante interface options. The amplifier shall mount in a standard 19 inch rack using two spaces (3.5. high) and weigh 24.7 pounds (11.2kg) or less.
Protea Digital Signal Processing for NE Multi-Channel
Protea is compatible with Microsoft Windows 8, 7 (Vista/XP) 32 & 64 bit systems. Audio professionals find our Protea DSP to be very intuitive and easy to navigate - and you will too.
https://ashly.com/warranty-information
800-828-6308