10 ms maximum
Cold-rolled steel
Base: 18 gauge (1.2 mm)
Cover: 19 gauge (1.1 mm)
850 mA maximum
24 VDC (regulated)
2.5 A maximum
8 A (all NAC and auxiliary outputs)
24 VDC (regulated)
-24 VDC (regulated)
19.6 VDC to 27.5 VDC (NAC when configured as power supply)
1.3 A maximum (NAC when configured as power supply)
24 VDC nominal (NAC when configured as power supply)
250 mVp-p (NAC when configured as power supply)
Form C
1.5 A at 32 VDC
4.5 A maximum (RMS)
120 VAC, 60 Hz or 220 VAC, 50 Hz
24 VDC nominal
120 VAC, 60 Hz, 4.2 A maximum or 240 VAC, 50 Hz, 2.5 A
85 VAC/120 VAC, 105 VAC/240VAC Supervised
24 VDC nominal, 10.2 A max. charging current
40 Ah maximum
24 VDC Regulated
8A
400 mV
200 mV
= 250 mV pp
150 mA (use for current calculation)
< 1.5 k Ohms
12/24 VDC/VAC (RMS) (compatible with NFPA 72 Class A or B NAC)
<= 10 ms (compatible with NFPA 72 Class A or B NAC)
15 mA maximum (compatible with NFPA 72 Class A or B NAC)
12 V nominal
5 VDC (NFPA 72 Class B, Style Y NAC or Class A, Style Z)
2.21K Ohms Bosch Security System, Inc. P/N: 25899 or Programmable from 1k Ohms to 20k Ohms (NFPA 72 Class B, Style Y NAC or Class A, Style Z)
24 VDC Regulated (NFPA 72 Class B, Style Y NAC or Class A, Style Z)
1.36 Ohms (maximum). Equivalent to 1.1 volt drop (NFPA 72 Class B, Style Y NAC or Class A, Style Z)
2.5 Supervised, Power Limited, Regulated (NFPA 72 Class B, Style Y NAC or Class A, Style Z)
19.7 to 27.5 VDC
750 mA
Form C
1.5 A, 30 VDC resistive load
Form C
1.5 A, 30 VDC resistive load
24 VDC Nominal (when NAC is Configured as a Power Output Circuit)
19.6 to 27.5 VDC (when NAC is Configured as a Power Output Circuit)
1.3 A maximum (when NAC is Configured as a Power Output Circuit)
250 mVpp (when NAC is Configured as a Power Output Circuit)
0 to 49 deg. C (32 to 120 deg. F)
Enclosure: 14.75 x 12.75 x 3.5" (37.47 x 32.39 x 8.89cm)
52 x 38 x 10.4cm (20.47 x 14.96 x 4.09") (without door)
Use the FPP-RNAC-8A-4C power supply to add four additional notification appliance circuits to a fire alarm control panel (when connected via the option bus) or as a NAC power supply for fire-protective signaling systems (when connected directly to the NAC output). The additional notification appliance circuits can be NFPA 72, Class B (Style Y) or Class A (Style Z). This regulated power supply provides up to 8A of power that is used to operate both continuous and intermittent loads. This 8A of power can be distributed through the four output circuits and auxiliary power circuit. The FPP-RNAC-8A-4C power supply is UL Listed for use in commercial fire alarm applications.
8 A of power
Fully supervised outputs
Configurable for NAC output or constant auxiliary power
Regulated 24 VDC output (nominal) with over-current protection
Built-in NAC patterns
Functions
Compatible Control Panel Connections
The FPP-RNAC-8A-4C power supply is compatible with any UL Listed control panel that uses reverse polarity supervised notification outputs with 12 VDC or 24 VDC regulated outputs. It is also compatible with the following Bosch Control Panels: D7022 Two-zone Conventional FACP, D8024 and D10024A Analog FACPs.
For the D7022 conventional panel and the D8024 and D10024A analog panels, the FPP-RNAC-8A-4C connects through a NAC circuit. No option bus connection is necessary.
D7024 Four-zone Addressable FACP
DS9400i Four-zone FACP
DS9400M AddressiFire FACP
Connect up to two FPP-RNAC-8A-4C power supplies to a D7024, DS9400i or DS9400M Control Panel. The control panel can individually control each of the four NAC outputs for each power supply. Only the four NAC outputs of a single power supply will be synchronized.
FPD-7024 or FPA-1000 Analog Addressable Fire Panels
Connect up to four FPP-RNAC-8A-4C power supplies to an FPD-7024 or an FPA-1000 control panel. Each RNAC's four NAC outputs will be synchronized and can be individually controlled for a total of 16 synchronized circuits.
NAC Output Patterns
The NAC circuits can be set to produce the following output patterns:
Steady
Temporal Code 3
Pulsed
California March
Wheelock Synch
Gentex Synch
System Sensor Synch
Status Displays
There are eight local status display LEDs on the power supply's printed circuit board that show the following conditions:
AC OK
System Trouble
Ground Fault
Input Active
Trouble Output 1, 2, 3 and 4
DIP Switch Settings
If connected to the fire alarm control panel's option bus, the power supply needs its own option bus address. Set this address through the DIP switches. Set the DIP switches to choose:
NAC or power supply output
NAC Input Variable option
AC Delay Time
Wiring
All wiring is connected to the power supply board by lift-gate terminals that can accept up to 12 AWG (ISO 4 mm2) wire.