CyberPower PR1500LCDRT2UN 1500VA/1350W Smart App Sinewave Rack/Tower UPS with RMCARD205 Card, 8x NEMA 5-15R

SKU: CYPR15LCDT2N

This item is no longer available.

Recommended Alternatives

Overview
Compare
Specs
Protection
Q&A

Questions & Answers

Reviews about this item

Review Summary

Select a plan in the Add Protection section above and purchase with this product by clicking “Add to Cart”.

image-protection

TRUSTED PROTECTION PLANS, EXCEPTIONAL SERVICE.

Invest In Your Gear and Peace Of Mind!

Accidents happen where life happens. Protect your favorite Adorama products and purchase a protection plan to stay covered from accidental damage, mechanical or electrical failure, and more.

Repair or Replacement

Repair or Replacement

If we can’t fix it, we’ll replace it at no additional cost.

Accidental Damage

Accidental Damage

Protect your product from drops, spills, and more.

Peace of Mind

Peace of Mind

Enjoy your gear without fear. We have you covered!

Malfunction Protection

Malfunction Protection

When regular use of your product over time results in mechanical or electrical failure.

Zero Deductible

Zero Deductible

We will never charge you a deductible after the purchase of a plan.

Customer-Focused Support

Customer-Focused Support

Our claims process is simple & easy and our customer service team is happy to help.

Adorama Protect powered by Extend is available for purchase to customers in the United States. Not available for purchase Internationally or in U.S. Territories.

CyberPower PR1500LCDRT2UN Specifications

General

General

Jump to...
  • UPS Topology

    Line Interactive

  • Energy Saving

    GreenPower UPS Bypass

  • Voltage

    80 - 150 VAC

  • Frequency Range

    47 - 63 Hz

  • Plug Type

    NEMA 5-15P

  • Plug Style

    Right Angle, 45 Degree Offset Right

  • Cord Length

    10' (3m)

  • VA

    1,500 VA

  • Watts

    1,350 W

  • Automatic Voltage Regulation

    Boost 1 +30%, Boost 2 +14% / Buck -12%

  • On Battery Voltage

    120 VAC +/- 5%

  • On Battery Frequency

    50/60 Hz +/- 0.1 Hz

  • On Battery Waveform

    Sine Wave

  • Outlet Type

    NEMA 5-15R

  • Outlets - Total

    8

  • Outlets - Critical Load

    4

  • Outlets - Battery & Surge Protected

    8

  • Outlets - Surge-Only Protected

    0

  • Outlets - Widely Spaced

    8

  • Overload Protection

    Internal Circuitry Limiting
    Circuit Breaker

  • Transfer Time

    4 ms

Battery

Jump to...
  • Runtime at Half Load

    11 minutes

  • Runtime at Full Load

    4 minutes

  • Battery Type

    Sealed Lead-Acid

  • Battery Size

    12V/7Ah

  • Battery Quantity

    4

  • Hot-Swappable

    Yes

  • User Replaceable

    Yes

  • Replacement Battery Cartridge

    RB1270X4F

  • Replacement Battery Cartridge Quantity

    1

  • Typical Recharge Time

    Less than 6 hours (90% charged)

Surge Protection & Filtering

Jump to...
  • Surge Suppression

    2,060 J

  • Phone RJ11 / Ethernet RJ45

    1-In, 1-Out (Combo)

  • Coaxial Protection RG6

    1-In, 1-Out

  • EMI/RFI Filtration

    Yes

Management & Communications

Jump to...
  • Multifunction LCD Panel

    Displays: Current/Load Level
    Runtime
    Battery Level
    Temperature
    Battery In Use
    Input Voltage
    Output Voltage
    Output Frequency
    Overload
    Wiring Fault
    Silent Mode
    Normal Mode

  • HID Compliant USB Port

    Yes

  • Serial Port

    Yes (2x)

  • Emergency Power Off (EPO) Port

    Yes

  • LED Indicators

    Power On
    Wiring Fault

  • Audible Alarms

    Input Fault
    Battery Fault
    Low Battery
    Overload

  • Software

    PowerPanel Business

  • SNMP / HTTP Remote Monitoring

    RMCARD205 included

  • AS400 Management

    None

Environmental

Jump to...
  • Operating Temperature

    32 - 104 Degree F (0 - 40 Degree C)

  • Operating Humidity

    0 - 95% (non-condensing)

  • Storage Temperature

    5 - 113 Degree F (-15 - 45 Degree C)

  • Maximum Operating Elevation

    10,000' (3000m)

  • Maximum Storage Elevation

    50,000' (15000m)

Certifications

Jump to...
  • Safety

    UL1778
    cUL 107.1
    FCC DOC Class B

  • Environmental

    RoHS Compliant

Physical

Jump to...
  • Rack Size

    2U

  • Form Factor

    Rack/Tower

  • Dimensions (W x H x D)

    17.25 x 3.5 x 15.75" (43.8 x 8.89 x 39.8cm)

  • Weight

    56.0 lbs (25.4kg)

About CyberPower PR1500LCDRT2UN

A rack/tower convertible UPS with line interactive topology and a pre-installed SNMP card, the CyberPower Smart App Sinewave PR1500LCDRT2UN provides battery backup, power protection (using sine wave output), and surge protection for corporate servers, department servers, storage appliances, network devices, and telecom installations requiring Active PFC power source compatibility. The PR1500LCDRT2UN uses Automatic Voltage Regulation (AVR) to correct minor power fluctuations without switching to battery power, which extends battery life. AVR is essential in areas where power fluctuations occur frequently. The RMCARD205, a remote management card that provides remote management and configuration of the UPS via a standard Web browser or network management system (NMS) comes installed

Battery Backup
Supplies power long enough for equipment to properly shut down when utility power fails. Helps prevent loss of data and minimizes the component stress caused by a hard shutdown.

Surge Protection
Diverts excess voltage away from sensitive electronic equipment during an AC power surge or power spike to prevent damage.

Data Line Protection
Prevents power surges that travel through telephone, coaxial, and Ethernet lines from causing damage to electronics.

Line Interactive Topology
Exists when a line interactive UPS has an autotransformer that regulates low voltages (e.g., brownouts) and over voltages (e.g., spikes) without having to switch to battery.

Automatic Voltage Regulation (AVR)
Provides clean, consistent AC power by automatically increasing (boosting) low voltage without using battery power when incoming utility power experiences minor fluctuations.

Sine Wave Output
Provides power protection to ENERGY STAR systems with Active PFC power supplies.

GreenPower UPS Bypass Design
Is a patented design that allows utility power to bypass the UPS transformer, when AC power is stable, which reduces energy consumption, noise, and heat buildup.

Rotatable Multifunction LCD Panel
Displays immediate, detailed information on the UPS battery and power conditions, alerting users to potential problems before they can affect critical equipment and cause downtime. The rotatable panel is easily readable whether the UPS is rack mounted or standing as a tower.

Rack/Tower Versatility
Allows for horizontal rack or vertical tower installation.

PowerPanel Business Edition Software
Provides IT professionals with tools for monitoring and managing the UPS and backup power. This software offers remote management functionality

Features

Efficient Remote Management
The Smart App Series offers full-featured network UPS management capabilities with the PowerPanel Business Edition software and an optional SNMP network management card. These remote management tools enable centralized power management, monitoring, control, and configuration. They also provide for safe shutdown of connected servers, workstations, and other devices via a standard Web browser or network management system (NMS).

Safe Shutdown
The PowerPanel Business Edition software, included with every Smart App Sinewave UPS, enables an administrator to remotely manage each aspect of the UPS and facilitate the orderly automatic shutdown of connected equipment in the event of an extended power outage. This software also provides comprehensive network power management for corporate servers and critical workstations supported by the UPS, such as application/operating system shutdown, event logging, reporting, alerts and notifications.

Programmable Outlet Control
Smart App UPS systems allow programming of critical outlets and non-critical outlets, giving administrators the ability to prioritize outlets and increase battery backup runtimes for the most critical equipment during extended power outages. Programmable outlet control also gives an administrator the option to delay-start non-critical outlets, permitting the internal batteries to fully recharge more quickly. This feature is vital to data centers where seamless, uninterrupted equipment bootup is a necessity.

GreenPower UPS Technology: Bypass Design
GreenPower UPS Technology from CyberPower improves operating efficiency, reduce heat generation, and consume less power than conventional UPS models.

Our patented Bypass Design allows current to bypass the transformer and automatic voltage regulation (AVR) when utility power is normal, thus reducing energy consumption and associated costs. Because utility power functions normally most of the time, the bypass design allows for substantial energy savings. This technology also reduces heat generation, an important factor in decreasing operating costs.

Automatic Voltage Regulation
Automatic Voltage Regulation (AVR) in line interactive UPS systems stabilizes the incoming AC signal to maintain output power at a nominal 120 volts by controlling high and low voltages without resorting to battery power. This significantly increases battery life and lessens the likelihood of data loss, memory freezes, and system crashes.

How AVR Works in a Line Interactive UPS
A line interactive UPS includes an AVR autotransformer a special type of transformer designed to switch between powered coils of wire in response to variances in utility power input, thereby increasing or decreasing the magnetic field and the resulting output voltage to connected equipment.

This type of UPS tolerates undervoltage brownouts and overvoltage surges without consuming backup battery power by automatically selecting different power taps on the AVR autotransformer. During normal operation, incoming AC power bypasses the autotransformer (where voltage highs and lows are controlled) while also charging the battery. When the incoming voltage falls below the AVR range, the UPS switches to battery backup, and the DC-AC inverter circuitry is engaged. Power will continue to be supplied by the battery-inverter circuit until incoming voltage returns to the range manageable by the AVR.

Typical Applications
Department Servers
Storage Devices
VoIP Installations
Automatic Voltage Regulation
Network Devices
Corporate Servers
Telecom Installations

CyberPower PR1500LCDRT2UN Features

  • Surge Protection
  • Data Line Protection
  • Line Interactive Topology
  • Automatic Voltage Regulation (AVR)
  • Sine Wave Output
  • GreenPower UPS Bypass Design
  • Rotatable Multifunction LCD Panel
  • Rack/Tower Versatility
  • PowerPanel Business Edition Software

Key Features

  • Surge Protection
  • Data Line Protection
  • Line Interactive Topology
  • Automatic Voltage Regulation (AVR)
  • Sine Wave Output
  • GreenPower UPS Bypass Design

What's in the box:

  • PR1500LCDRT2UN 1500VA/1350W Smart App Sinewave Rack/Tower UPS with RMCARD205 Card
  • 2x Rack Mount Brackets
  • Metal Stand Plate
  • Telephone Cable (Black)
  • Emergency Power Off Cable (Gray)
  • PowerPanel Business Edition Software CD
  • 2x Serial Interface Cable (DB-9)
  • 4x Rubber Buffers
  • USB A+B Type Cable
  • User Manual
  • CyberPower 3 Year Limited Warranty