Drobo B810i Specifications

  • Connectivity

    2x Gigabit Ethernet ports for data
    1x Gigabit Ethernet port for management

  • Drives and Expansion

    Up to 8 SATA or solid-state drives (SSDs)
    4KN disk support
    Drives of any manufacturer, capacity, spindle speed and/or cache can be used
    No tools required for 2.5" SSD carriers
    Expandable by adding Drives or hot-swapping existing Drives with larger ones

  • BeyondRAID Features

    Thin Provisioning
    Instant Expansion
    Mixed Drive Size Utilization
    Automatic protection Levels Background Data Integrity Scrubbing
    Single or Dual Disk Redundancy
    Virtual hot Spare
    Data Aware
    Drive Re-ordering

  • Management

    Drive bay indicator lights, capacity gauge, status lights
    Drobo Dashboard version 2.7 or later
    Drobo Dashboard email alerts

  • File Systems Supported

    Mac OS X: HFS+
    Windows: NTFS
    VMware: VMFS

  • Network Protocols

    iSCSI
    CHAP Authentication
    MPIO support

  • Ethernet Features

    Jumbo frames (up to 9000 bytes MTU)

  • Hardware

    Carrier-less drive bays for 3.5" drives
    Rackmount Kit 19"

  • Form Factor

    Desktop or 3U Rack Mount

  • Additional Software Features

    Hybrid Storage
    Automated Data-Aware Tiering
    Automated hot Data cache
    Drive Spin Down
    Utilizing Linux version 3.2

  • Power and Cooling

    Internal power supply: AC Input 100/240 VAC, 1.8/0.75 A, 50/60 Hz
    Power Consumption:
    Idle System (standby, drives off): 13 W
    Typical Idle System (drive spin down mode, eight (8) drives): 25 W
    Typical Busy System four (4) drives): 82 W Dual, fixed cooling fans

  • Environmental

    Acoustics, Normal Operation: 30.4 dB

  • Operating Temperature

    50 to 95deg. F (10 to 35deg. C)

  • Non-Operating Temperature (storage)

    14 to 140deg. F (-10 to 60deg. C)

  • Operating Humidity

    5% - 80%

  • Certifications

    Environmental: RoHS, WEEE, REACH
    Regulatory: FCC Part 15 Class B; Canada ICES-003 Class B; CE Mark; CISPR22 Class B; VCCI Approval to V.3; ACA Approval to AS/NZS 3548
    Safety: UL, cUL, CB

  • Dimensions (W x H x D)

    12.70 x 5.46 x 14.10" (322.58 x 138.68 x 358.14 mm)

  • Weight

    16.3lbs (7.4kg) (without hard drives, or packaging)

  • UPC Code

    850737006598

About Drobo B810i

Optimizing Business Applications
The Drobo B810i disrupts IT economics by delivering advanced iSCSI SAN storage capabilities reserved for expensive enterprise solutions. It is optimized for small and medium-sized businesses that don't have dedicated IT support and it is used to simplify and consolidate both physical and virtual storage in a single array with "on-demand" ability to scale both capacity and performance.

With Data-Aware Tiering, the B810i's ability to automatically tier frequently used transactional data from stored data that's seldom used enables businesses to consolidate storage resources and share that storage across all connected clients and their applications. The B810i model allows for a more effective work collaboration, the storage of creative workflows and a trustworthy, easy-to-use backup system.

Leave Your Limitations Behind Go BeyondRAID
Built on their award-winning BeyondRAID technology, the Drobo B810i protects your data without any intervention - even in the event of multiple drive failures. You can even switch from single to dual disk redundancy with a single click, ensuring enterprise-level dual parity data protection when required. Drobo's with BeyondRAID are also self-healing and have virtual hot-spares. If a drive happens to fail, Drobo will automatically re-layout the data to return to a protected state without disruption.

Drobo takes the up front guess work out of determining the amount of capacity you require. Buy the capacity you need today and when you need more storage, simply replace your smallest drive with a larger one and immediately use that capacity in seconds. You can even mix and match drive brands, capacities and speeds.

To further enhance your experience, every Drobo comes with Smart Volume technology. Smart Volumes are thinly provisioned volumes that automatically utilize capacity as needed from a common pool of storage. Additionally, as data is deleted, free capacity is returned to that common pool, immediately increasing the available capacity. BeyondRAID along with Smart Volumes deliver next-generation storage technology by bringing together enhanced data protection, reliability, expandability and ease-of-use.

Pain Free Expansion
Expanding your storage capacity with a Drobo couldn't be easier. There's no long, risky process to add capacity to a Drobo - no need to go through the time consuming and complex administration of destroying your RAID sets and recreating with larger drives; and then finally restoring from your backup. When it's time to add storage capacity to a Drobo, simply insert additional disk drives or replace the smallest disks with larger ones. The unique, carrier-less drive-bay design results in efficient and pain free scalability that won't leave you running out of space when you need it most.

If you're running low on space, the lights on the front of the Drobo B810i tell you exactly what to do. The innovative, user-friendly industrial design allows you to add or hot-swap larger capacity drives, without tools, on the fly, for storage expansion with zero downtime. Expand your capacity without missing a beat while safely storing, sharing and backing up all your data with ease and peace of mind. It's that simple!

Automated Data-Aware Tiering
The Drobo B810i moves beyond the days of manually tuning an array for applications that have different storage requirements. Automated Data-Aware Tiering leverages high-capacity hard disk drives (HDDs) paired with high-performance solid state drives (SSDs) to deliver application-optimized storage that requires no manual tuning.

Data-Aware Tiering automatically and seamlessly migrates the most frequently accessed data to the faster SSD drives and the less accessed data to the high capacity hard disk drives. As data access patterns change, the data is automatically relocated to maximize performance while still benefiting from the large capacity drives.

Build an iSCSI SAN with Drobo
Unfamiliar with iSCSI? iSCSI is a popular high-performance protocol for deploying storage networking technology in IT environments. The problem: it can be very complex to manage. The Drobo B810i changes that by introducing zero-click iSCSI configuration for both Windows and Mac OS X servers.

With an iSCSI SAN, centralized storage is provided to each server over a high-speed Gigabit Ethernet network where it can be allocated or expanded instantaneously. Deploying a Drobo B810i eases iSCSI adoption, simplifies administration and allows you to consolidate storage so you have fewer devices to manage.

Optimized for Business
The Drobo B810i is ideal for building your first scalable backup server or expanding your storage to your existing file servers. It integrates seamlessly into your TCP/IP network infrastructure and utilizes the industry-standard iSCSI protocol to provide simple, consolidated storage for your servers.

Rack Mount Ready, Desktop Quiet
Drobo B810i can be deployed in a server room for IT use or on a desktop for workgroup sharing of storage, thanks to its compact design and quiet operation. Dual smart fans automatically manage their speeds to optimize cooling and minimize operating noise. You can even configure Drobo to spin down drives when they're not in use to further reduce noise and save energy. (Drobo B810i Rack Mount sold separately).

What's in the box:

  • Drobo B810i 8-Bay iSCSI SAN Storage Array
  • 3x 6' (1.8m) Ethernet Cables
  • 6' (1.8m) Power Cord with Power Supply
  • Quick Start Guide
  • Internal LED Labels for Front Panel (Dutch
  • French and Japanese)
  • Drobo 1 Year Warranty