See Options
1 Year
$169.00
2 Year
$289.00
3 Year
$429.00
Need help? Ask our experts.
Review Summary
Accidents happen. Protect your favorite Adorama products and purchase a protection plan to stay covered from accidental damage, mechanical or electrical failures, and more.
If we can’t fix it, we’ll replace it at no additional cost.
Protect your product from drops, spills, and more.
Enjoy your gear without fear. We have you covered!
When regular use of your product over time results in mechanical or electrical failure.
We will never charge you a deductible after the purchase of a plan.
Our claims process is simple & easy and our customer service team is happy to help.
Adorama Protect powered by Extend is available for purchase to customers in the United States. Not available for international or U.S. territories purchases. Plans on open box items do not cover pre-existing damage.
Adorama Protect plans are available for ABS clients. If you have any questions or require assistanse, please call 800-223-2500
Browse our FAQ
2000 VA
1800W
100VAC-120VAC
Low Voltage 80 VAC/70 VAC/60 VAC/55 VAC +/- 5% (based on load percentage 100%-80% / 80%-70% / 70%-60% / 60%-0)
Low Voltage Re-Transfer 85 VAC/75 VAC/65 VAC/60 VAC +/- 5%
High Voltage Re-Transfer 142 VAC +/- 5%
High Voltage 150 VAC +/- 5 %
50Hz/ 60Hz
>=0.99 at nominal voltage
5-20P
100/110/115/120VAC
+/-1%
47 - 53 Hz or 57 - 63Hz (Synchronized Range)
50Hz +/- 0.5% or 60Hz +/- 0.5% (Bat. Mode)
5:1 (max.)
<2% (Linear load)
8% max (Battery mode before shut down)
AC to DC: Zero
Inv. to Bypass: 4 ms (Typical)
Pure Sinewave
(8) 5-20R
88% (typical), 90% (peak)
85% (typical), 88% (peak)
(4) 12V/9Ah
2.7 minutes full load, 10 minutes half load
4 hours recover to 90% capacity
1 Amp
54.7 VDC +/- 1%
Load level 0-25%, 26-50%, 51-75% and 76-100%, Low Battery and Battery Good, Programmable Management Outlets working, UPS On-Line, UPS in Frequency Converter Mode, UPS On Bypass, Alarm Disabled Indicator and Battery Charger Working
Input Voltage and Frequency, Output Voltage and Frequency, Battery Backup Time (hours/minutes), Fault Indicator, Battery Voltage, Overload, and/or UPS Output is short circuited
Off/Enter - Turn UPS Off, Switch LCD Message, Mode Settings, Navigation Key, On/Mute + Select Button to switch to Bypass Mode
Low battery, Overload, Battery Not Connected, Overcharge, Site Wiring Fault, EPO Enabled, Over Temperature, Charger Failure, Battery Fault, Bypass Out of Range and Bypass Frequency Unstable
0 to 40 deg. C (32 to 104 deg. F)
20-90 % RH (non-condensing)
-25 to 40 deg. C (-13 to 104 deg. F) Batteries (Refresh Charge at 3 months)
Less than 50dBA at 1 Meter
Supports Windows 2000/2003/XP/Vista/2008/7, Linux, Unix, and Mac
UL1778/cUL
Rack Mount (2U): 3.39 x 17.24 x 20.38" (86.11 x 437.90 x 517.65mm)
Tower (2U): 17.24 x 3.39 x 20.38" (437.90 x 86.11 x 517.65mm)
47 lbs (21.32kg)
Find the ultimate solution for your power needs with the UniStar V Series SCV-20001 1800W 2RU On-Line Double-Conversion Power Saving Uninterruptible Power Supply. With a robust 2000VA capacity, this advanced UPS system is designed to provide reliable, high-quality power to your mission-critical devices, including sensitive networks, small computer center servers, telecom applications, and industrial equipment.
The UniStar V Series SCV-20001 is engineered with advanced processor circuitry and an output power factor of 0.90, ensuring high performance and efficiency for your critical applications. Its high-efficiency circuitry converts 90% of available current into real work, reducing equipment and operating costs.
This UPS system features a true double conversion architecture that buffers connected loads from incoming disturbances on the AC line and neutral, providing unconditional voltage stability regardless of local utility grid issues. Its user-friendly LCD display offers real-time indication of all major system parameters and status, including load and battery levels and fault signals.
The UniStar V Series SCV-20001 is designed for flexibility, with a convertible tower/rack design that allows for easy integration into various environments. It comes with programmable power management outlets for independent control of load segments, extending battery time during power failures by shutting down non-critical devices.
This UPS system also features an ECO mode for energy saving, operating at high efficiency up to 97% when supplied by the mains. In case of a mains failure, the inverter takes over the load, ensuring supply continuity to the connected systems. It even offers an advanced ECO mode, allowing the UPS to operate at higher efficiency up to 98%.
The UniStar V Series SCV-20001 also includes an Emergency Power Off (EPO) function for securing personnel and equipment during emergencies, and a hot-swappable battery design for uninterrupted power during battery replacement. It ships with NetAgent9 management software, floor stand, and rack mounting hardware for easy installation and management.
Experience the latest in single-phase technology with the UniStar V Series SCV-20001. Its on-line performance provides a constant clean, steady sine wave, safeguarding your most sensitive equipment. With its double conversion technology, it regenerates utility power to correct electrical disturbances in the mains, ensuring clean AC power with voltage and frequency independent from the utility.
This UPS system is equipped with a wide frequency and voltage windows, near unity input power factor, and overload protection. It also features user controls, DC-start function, programmable receptacles, emergency shutdown control, communication software, custom options slot, and a user-friendly plug-and-play design.
The UniStar V Series SCV-20001 is your reliable power protection solution, designed to meet the demands of servers, networks, telecommunications, industrial equipment, and manufacturing processes. Protect your critical devices with this high-density, high-efficiency UPS system.