See Options
1 Year
$229.00
2 Year
$389.00
3 Year
$599.00
Need help? Ask our experts.
Review Summary
Accidents happen. Protect your favorite Adorama products and purchase a protection plan to stay covered from accidental damage, mechanical or electrical failures, and more.
If we can’t fix it, we’ll replace it at no additional cost.
Protect your product from drops, spills, and more.
Enjoy your gear without fear. We have you covered!
When regular use of your product over time results in mechanical or electrical failure.
We will never charge you a deductible after the purchase of a plan.
Our claims process is simple & easy and our customer service team is happy to help.
Adorama Protect powered by Extend is available for purchase to customers in the United States. Not available for international or U.S. territories purchases. Plans on open box items do not cover pre-existing damage.
Adorama Protect plans are available for ABS clients. If you have any questions or require assistanse, please call 800-223-2500
Browse our FAQ
3000 VA
2700W
100VAC-120VAC
Low Voltage 80 VAC/70 VAC/60 VAC/55 VAC +/- 5% (based on load percentage 100%-80% / 80%-70% / 70%-60% / 60%-0)
Low Voltage Re-Transfer 85 VAC/75 VAC/65 VAC/60 VAC +/- 5%
High Voltage Re-Transfer 142 VAC +/- 5%
High Voltage 150 VAC +/- 5 %
50Hz/ 60Hz
>=0.99 at nominal voltage
L5-30P
100/110/115/120VAC
+/-1%
47 - 53 Hz or 57 - 63Hz (Synchronized Range)
50Hz +/- 0.5% or 60Hz +/- 0.5% (Bat. Mode)
5:1 (max.)
<2% (Linear load)
8% max (Battery mode before shut down)
AC to DC: Zero
Inv. to Bypass: 4 ms (Typical)
Pure Sinewave
(4) 5-20R & (1) L5-30R
88% (typical), 90% (peak)
85% (typical), 88% (peak)
(6) 12V/9Ah
2.7 minutes full load, 10 minutes half load
4 hours recover to 90% capacity
1 Amp
82.1VDC +/- 1%
Load level 0-25%, 26-50%, 51-75% and 76-100%, Low Battery and Battery Good, Programmable Management Outlets working, UPS On-Line, UPS in Frequency Converter Mode, UPS On Bypass, Alarm Disabled Indicator and Battery Charger Working
Input Voltage and Frequency, Output Voltage and Frequency, Battery Backup Time (hours/minutes), Fault Indicator, Battery Voltage, Overload, and/or UPS Output is short circuited
Off/Enter - Turn UPS Off, Switch LCD Message, Mode Settings, Navigation Key, On/Mute + Select Button to switch to Bypass Mode
Low battery, Overload, Battery Not Connected, Overcharge, Site Wiring Fault, EPO Enabled, Over Temperature, Charger Failure, Battery Fault, Bypass Out of Range and Bypass Frequency Unstable
0 to 40 deg. C (32 to 104 deg. F)
20-90 % RH (non-condensing)
-25 to 40 deg. C (-13 to 104 deg. F) Batteries (Refresh Charge at 3 months)
Less than 50dBA at 1 Meter
Supports Windows 2000/2003/XP/Vista/2008/7, Linux, Unix, and Mac
UL1778/CE/cUL
Rack Mount (2U): 3.39 x 17.24 x 27.74" (86.11 x 437.90 x 704.60mm)
Tower (2U): 17.24 x 3.39 x 27.74" (437.90 x 86.11 x 704.60mm)
65 lbs (29.48kg)
Bring unparalleled reliability and efficiency to your critical systems with the UniStar V Series SCV-30001 2700W 2RU On-Line Double-Conversion Power Saving Uninterruptible Power Supply. With a robust 3000VA capacity, this high-performance UPS is engineered to deliver a consistent and clean power supply, ensuring the protection and uninterrupted operation of sensitive electronic equipment.
The UniStar V Series SCV-30001 stands out with its true on-line, double-conversion architecture, which isolates connected devices from any disturbances on AC lines, providing unconditional voltage stability. This advanced design is crucial for maintaining the integrity of mission-critical devices such as network servers, telecom applications, and industrial equipment, safeguarding against data loss and downtime.
Experience the benefits of a user-friendly interface with an easy-to-read LCD display that offers real-time monitoring of system parameters, including load and battery levels, as well as immediate fault signal recognition. The display can be easily adjusted to fit both tower and rack mount installations, enhancing the versatility of this UPS.
The UniStar V Series is not only reliable but also efficient, featuring an output power factor of 0.9. This ensures that 90% of the current is effectively converted into usable watts, reducing operating costs and maximizing performance for your critical applications. Additionally, the UPS boasts ECO and Advanced ECO modes, which elevate energy efficiency to up to 98%, minimizing energy consumption while maintaining protection.
For extended power requirements, the UPS allows for the addition of optional external batteries, which can be hot-swapped to maintain continuous operation during replacement, further enhancing the system's reliability. The innovative battery management system extends the lifespan of the batteries by optimizing the discharge process.
The UniStar V Series SCV-30001 is equipped with programmable power management outlets, enabling independent control of load segments. This feature allows for prioritization of power supply to essential devices during outages, while non-critical devices can be powered down to conserve battery life.
Safety is paramount with the Emergency Power Off (EPO) function, which can be activated in urgent situations to protect personnel and equipment. The UPS also features a wide input voltage and frequency window, accommodating a variety of power conditions and ensuring longevity of the battery.
Communication is made simple and effective with the included NetAgent9 management software, which facilitates remote monitoring and management, ensuring your systems are always under vigilant supervision.
Designed for a range of applications, from broadcast and manufacturing to healthcare and education, the UniStar V Series SCV-30001 UPS is the ideal solution for anyone seeking a durable, efficient, and advanced power protection system. Its rack/tower design, hot-swappable batteries, and programmable outlets make it a top choice for safeguarding your essential operations against power interruptions.