The UPS8-2000 2000VA Line Interactive UPS in the bundle provides clean, stable power to your devices during power fluctuations or outages. It's designed to protect your critical data and equipment from power problems.
The UPS-XBDM-20RHW Hardwired Bypass Module is used to bypass the UPS and allow the power to continue flowing to your devices in the event of a UPS failure. It ensures continuous uptime for critical electronics.
The auto-restart feature ensures that the UPS automatically resumes operation when utility power is restored after a full battery discharge. This feature offers convenience and ensures your devices remain powered.
Temperature-compensated charging is a feature that adjusts the charging rate based on the battery's temperature. This helps to prolong battery life and reduce replacement costs.
The programmable receptacle group allows you to prioritize uptime for critical loads by shedding less critical ones. This feature is particularly useful in situations where you need to maximize the uptime of essential equipment.
Review Summary
Accidents happen where life happens. Protect your favorite Adorama products and purchase a protection plan to stay covered from accidental damage, mechanical or electrical failure, and more.
If we can’t fix it, we’ll replace it at no additional cost.
Protect your product from drops, spills, and more.
Enjoy your gear without fear. We have you covered!
When regular use of your product over time results in mechanical or electrical failure.
We will never charge you a deductible after the purchase of a plan.
Our claims process is simple & easy and our customer service team is happy to help.
Adorama Protect powered by Extend is available for purchase to customers in the United States. Not available for purchase Internationally or in U.S. Territories.
Browse our FAQ
2000VA (1800W)
120VAC
-32% to +27% without use of battery
50/60Hz auto-sensing
120VAC nominal (110/115/127 selectable)
Pure sine wave
2-6ms
Up to 99% ECO mode, 95% buck and boost mode
2% at 100% linear load; 5% at 100% non-linear load
Sealed, maintenance-free lead acid
(4) 12V 9AH
1.5A max
4 hours to 90%
(8) NEMA 5-15/20R
6' (1.83m), 5-20P
32 to 104 deg. F (0 to 40 deg. C)
< 45dBA
11500' (3505.24m) above sea level
UL, cUL, RoHS
RS-232, USB, EPO, intelligent slot for optional cards (Web/SNMP, Relay/dry contact)
120VAC/20A
Hardwired terminal block
Hardwired terminal block + (6) 5-15R
20A break before make rocker switch
8ms
5-20R
3' (0.91m) cord with 5-20P plug
6500A, 114J, 330VAC
Utility, surge, UPS
UPS: 17.2 x 18.9 x 3.5" (436.88 x 480.06 x 88.90mm)
Hardwired Power Cord: 17 x 3.5 x 1.75" (431.80 x 88.90 x 44.45mm)
UPS: 47.4 lbs (21.50kg)
Hardwired Power Cord: 3.6 lbs (1.63kg)
Discover the UPS8-20-HW Bundle, an essential power protection solution that combines the high-performance UPS8-2000 2000VA Line Interactive UPS with the innovative UPS-XBDM-20RHW Hardwired Bypass Module for a comprehensive backup power system. This advanced bundle is engineered to safeguard your critical data and equipment against power disturbances, ensuring your operations remain uninterrupted.
The UPS8-2000 Line Interactive UPS delivers pure sine wave output, providing the highest efficiency and network-grade power quality for your AV electronics, servers, and network equipment. With a robust power rating of 2000VA, this UPS is designed to handle significant power requirements with ease. The smart LCD display on the front panel offers vital monitoring and precise information at a glance, allowing for better control and management of your power supply.
Experience the convenience of the auto-restart feature, which ensures the UPS8 automatically resumes operation when utility power is restored after a full battery discharge. The highly efficient operation in ECO mode boasts a 99% efficiency rate, reducing energy consumption and contributing to a greener environment.
The programmable receptacle group is a standout feature, enabling you to prioritize uptime for critical loads by shedding less critical ones. Temperature-compensated charging extends battery life and minimizes replacement costs, while the hot-swappable battery design allows for easy replacement without interrupting the connected load.
Installation flexibility is a key advantage, with two mounting formats included:
- A 4-point rackmount rail kit with horizontal brackets for secure rack installation.
- Tower pedestals for versatile non-rackmount applications.
The UPS-XBDM-20RHW Hardwired Bypass Module complements the UPS by providing a seamless maintenance bypass. It features hardwired terminal block connections for both input and output, ensuring continuous uptime for your critical electronics. The manual bypass switch allows for the transfer of critical loads from UPS power to utility power, facilitating UPS maintenance or replacement without disrupting power to your devices. The switch ensures a rapid transfer within 8ms, minimizing downtime and simplifying UPS management.
LED indicators on the bypass module confirm the availability of UPS and utility power sources, while the power distribution system includes six 5-15R output receptacles. Surge protection is maintained even when the UPS is in bypass mode, protecting both your loads and the UPS electronics during normal operation.
For added installation versatility, the bundle comes with both wall and rackmount hardware, accommodating various setup preferences. The power rating for the bypass module is 120VAC / 20A, ensuring compatibility with a wide range of electronic devices.
Choose the UPS8-20-HW Bundle for a reliable, durable, and high-performance power backup solution that keeps your essential equipment running smoothly, even during unexpected power disruptions.