
See Options
Need help? Ask our experts.
The Cyanovac I utilizes vacuum technology for a more uniform glue-fuming process, reducing the risks of over or under fuming. Its advanced design ensures comprehensive coverage, even in intricate areas, making it highly effective for developing latent fingerprints on a variety of surfaces.
The Cyanovac I features a spacious chamber with a length of 16 inches and a diameter of 10 inches. This generous size accommodates a wide range of object sizes and shapes for versatile forensic fuming.
The Cyanovac I is equipped with a clear polycarbonate lid that allows for real-time visual monitoring of the fuming process. This feature enables users to observe the progress of the development without interrupting the process.
Yes, the Cyanovac I is designed for user-friendly operation. It features a precision vacuum switch control that maintains the ideal fuming environment, making the process straightforward and simple for forensic professionals.
The chamber of the Cyanovac I is constructed with heavy, 0.365-inch-thick aluminum walls. This robust construction ensures the chamber's structural integrity under repeated use.
Review Summary
0.365" Aluminum
16x10" / 40.64x25.4cm
Discover the advanced capabilities of the Cyanovac I Laboratory Fuming Chamber Outfit, a cutting-edge solution for forensic professionals seeking to enhance the development of latent fingerprints on challenging surfaces. The Cyanovac I is expertly designed to address the complexities of glue-fuming large, irregularly shaped, or textured items such as wrinkled plastic bags, ensuring that the days of requiring items to be completely unfolded are behind us.
With traditional cyanoacrylate chamber fuming, the risk of uneven fume distribution was significant, leading to over-fumed or inadequately fumed areas. However, the Cyanovac I utilizes vacuum technology to deposit glue on fingerprint ridge structures uniformly, resulting in consistent and well-distributed fingerprint development. This innovative approach minimizes the likelihood of over-fuming, a common issue with non-vacuum methods.
The Cyanovac I's vacuum environment optimizes glue distribution within the chamber, allowing fumes to navigate effortlessly around corners and into the recesses of the items being processed. This feature ensures comprehensive coverage and detailed fingerprint development, even in the most intricate areas.
At the heart of the Cyanovac I is the Sirchie VAC150, a vacuum chamber that embodies the forefront of forensic fuming technology. The chamber's spacious interior measures 16 inches in length and 10 inches in diameter, accommodating a wide range of object sizes. Constructed with heavy, 0.365-inch-thick aluminum walls, the VAC150 maintains its structural integrity under the rigors of repeated use.
The chamber is equipped with a robust, diaphragm-type pump, meticulously controlled by a precision vacuum switch, to maintain the ideal fuming environment. The operation of the VAC150 is both intuitive and user-friendly, designed to streamline the fuming process for forensic experts.
A clear polycarbonate lid tops off the chamber, providing users with the ability to visually monitor the fuming process without interrupting it. This feature ensures that users can observe the progress of the development in real-time, making adjustments as necessary to achieve the best possible results.
In summary, the Cyanovac I Laboratory Fuming Chamber Outfit is an indispensable tool for forensic science, offering unparalleled control and consistency in the development of latent fingerprints on a variety of surfaces. Its thoughtful design and user-centric features make it a must-have for any crime scene investigation team committed to accuracy and efficiency in evidence processing.
800-356-7311