Browse our FAQ
100-240V AC, 50/60Hz
24V DC nominal (12 to 30V DC), 65 to 150mA MS-2002 is capable of supplying 1 amp per channel overall
-20 deg. C to 80 deg. C / -4 deg. F to 176 deg. F; 0% to 95% humidity, non-condensing
-15 deg. C to 60 deg. C / 5 deg. F to 140 deg. F; 0% to 95% humidity, non-condensing
50 to 200Ohms, dynamic (balanced or unbalanced)
150 to 600Ohms, monaural
XLR-4M
Pin 1: Microphone low
Pin 2: Microphone high
Pin 3: Headphone high
Pin 4: Headphone low
Electret condenser
Phantom (+5V DC)
-42dBu
-25dBu
IKP12 (MCP-90 series, stereo plug connector)
2.3VrmsmAximum, 1.0Vrms nominal
25 +/-3dB
2.3VrmsmAximum, 1.0Vrms nominal
75k
Greater than 50dB
9-pin female D-sub (DE9S)
Pin 1: Ground
Pin 2: Program 1 input low
Pin 3: Program 2 input low
Pin 4: NC
Pin 5: NC
Pin 6: Program 1 input high
Pin 7: Program 2 input high
Pin 8: NC
Pin 9: NC
Balanced Mode: 1 Vrms nominal
Unbalanced Mode: 1 Vrms +/-10%
Balanced Mode: 300Ohms
Unbalanced Mode: 150Ohms
Balanced Mode: greater than 10000Ohms
Unbalanced Mode: greater than 10000Ohms
Balanced Mode: -40dB, 35dB adjustable range
Balanced Mode: 20kHz +/-100Hz, 0.5 Vrms +/-10%
Unbalanced Mode: 11 +/-3 VDC
Balanced Mode: 20kHz +/-800Hz, 100 mVrms
Unbalanced Mode: 4 VDC minimum
Balanced Mode: 24kHz +/-300Hz, 0.5 Vrms +/-10%
Balanced Mode: 24kHz +/-800Hz, 100 mVrms
Balanced Mode: less than -70dB
Balanced Mode: greater than 50dB
Balanced Mode: One XLR-3M and XLR-3F pair, wired in parallel, for each channel (permits "loop-thru" connection)
Two XLR-6M (Neutrik) connectors for 2-channel connection
Unbalanced Mode: Uses same connectors as for balanced mode, above but with pinouts modify ed by BAL/UNBAL switch on back panel as follows:
Balanced Mode: Pin 1: Common
Balanced Mode: Pin 2: Intercom audio low and +24V DC input
Balanced Mode: Pin 3: Intercom audio high and +24V DC input
Unbalanced Mode: Pin 1: Common
Unbalanced Mode: Pin 2: +24 VDC input
Unbalanced Mode: Pin 3: Intercom audio high
Pin 1- Audio and DC Common
Pin 2- Local power (12 to 15V DC, 65 to 150mA)
Pin 3- Intercom channel 1 audio low and +24V DC phantom power
Pin 4- Intercom channel 1 audio high and +24V DC phantom power
Pin 5- Intercom channel 2 audio low and +24V DC phantom power
Pin 6- Intercom channel 2 audio high and +24V DC phantom power
Pin 1- Common
Pin 2- Local power (12 to 15 VDC, 65 to 150mA)
Pin 3- Channel 1 +24 VDC input
Pin 4- Channel 1 Intercom audio high and DC call
Pin 5- Channel 2 +24 VDC input
Pin 6- Channel 2 Intercom audio high and DC call
235 mVrms nominal
1/8" Stereo Phone Jack
PA output high
Not used
Common
0dB nominal (1.0 Vrms)
1000Ohms nominal
200Hz to 8kHz +1/-3dB
RCA Phono Jack
Speaker output high
Common
2.0 mm stereo phone jack
Talk output
Listen input
Common
30 +/-3dB
250mW +/-10% into 150Ohms, 65mW +/-10% into 600Ohms
200Hz to 8kHz +1/-3db
2kHz, at the headphones
Less than 0.2% at 200mW
1.75 x 19 x 10.31" / 44.45 x 482.6 x 261.87mm
Approximately: 4.5lbs / 2.04kg
The MS-2002 is a complete 2-channel master station and system power supply (24 V DC, 2 Amps total power) in a single unit. You simply plug it into any AC power outlet from 100 to 240 volts, add a microphone or headset, connect intercom stations to the back panel and you're ready to communicate. It has combined 1-channel and 2-channel connectors, so you don't have to add a separate breakout box if you want to mix 1-channel and 2-channel intercom stations. It fits in a standard 19-inch equipment rack and is one (1) rack unit high. It can communicate with two (2) intercom channels.
Speaker Station or Headset Station uses the Built-In Speaker for listening and add an optional RTS MCP- 90 series Gooseneck Panel Microphone for talkback. You can also turn off the speaker volume and plug in headsets for private communication. Voice Activated Microphone (VOx) separate controls adjust the voice activation level for the headset microphone and panel microphone inputs. Public Address (PA) Output, with PA key uses your intercom microphone to talk over a PA system. Back-lit Keys improves visibility in low-light Incoming Call Indications with red flashing call light, with beep tone if desired. Instantaneous Auto-Reset technology in performance and safety, which uses a revolutionary new circuitry that dynamically monitors line fault conditions. Then, when the fault is removed, automatically brings individual power supply channels up.
Mic Kill Key can turn off all microphones on a channel to quickly clear the channel. Program Input for Each Channel connect any line-level audio source for monitoring in the speaker or headset, or for routing to the intercom channel. The program audio to the channel can be set to interrupt while the MS-2002 operator is talking on the channel. Binaural (Stereo) Listening with External powered speakers can connect external powered speakers and then monitor channel 1 and 2 as separate right and left audio. Expand channels by connecting optional EMS-4001 Expansion Stations. It is clear-com compatible.