1000VA/1000W, 1500VA/1350W, 2000VA/1800W, 3000VA/2700W
Typical: 120V
Range: 60-150V
40-70Hz; Auto Sensing
1000VA: 10' (3.04m) attached w/ NEMA 5-15P plug
1500VA: 10' (3.04m) attached w/ NEMA 5-15P A plug
2000VA: NEMA L5-20P or 5-20P plug (5-20P adapter included)
3000VA: 10' (3.04m) attached w/ NEMA L5-30P plug
1000VA and 1500VA: 6x 5-15R
2000VA: 6x L5-20R+5-20R
3000VA: 6x L5-30R+5-20R
1000VA: 110/115/120/125VAC (user-configurable); +/-3%
1500VA, 2000VA and 3000VA: 110/115/120VAC (user-configurable); +/-3%
Sine wave
1000VA:
>200% for 250ms;
150-200% for 50 seconds;
125-150% for 60 seconds;
105-125% for 60 seconds
1500VA:
>200% for 250ms;
150-200% for 2 seconds;
125-150% for 50 seconds;
105-125% for 60 seconds
2000VA:
>200% for 250ms;
150-200% for 2 seconds;
125-150% for 50 seconds;
105-125% for 60 seconds
3000VA:
>200% for 250ms;
150-200% for 2 seconds;
125-150% for 10 seconds;
105-125% for 15 seconds
+32 Degree F to +104 Degree F (0 Degree C to 40 Degree C)
4 Degree F to +140 Degree F (-20 Degree C to 60 Degree C)
Contain batteries will be from 5 Degree F to 104 Degree F (-15 Degree C to 40 Degree C)
0% to 95%, Non-condensing
10000' (3000m)
50000' (15000m)
1000VA: <46dBA max @ 3' (1m) front and sides < 43dBA, at 3' (1m) rear
1500VA: <46dBA at 3' (1m) front and side < 45dBA at 3' (1m) rear
2000VA and 3000VA: <48dBA max @ 3' (1m) front and side <48dBA max @ 3' (1m) rear
ANSI C62.41 Category B
ISTA Procedure 1A
UL 1778 4th Edition and CSA 22.2 No 107.3
FCC Part 15 (Class A) - CISPR22 Class A (RFI)
WEEE and ROHS2 REACH
Valve-regulated, non-spillable, lead acid
1000VA:
100% Load: 6.7
50% Load: 17.9
1500VA:
100% Load: 6.7
50% Load: 18.8
2000VA:
100% Load: 4
50% Load: 12.3
3000VA:
100% Load: 4
50% Load: 12.3
1000VA:
100% Load: 32.6
50% Load: 76.5
1500VA:
100% Load: 32.4
50% Load: 79.7
2000VA:
100% Load: 22
50% Load: 53.6
3000VA:
100% Load: 22.2
50% Load: 54.6
Required, included
Lead acid
Non-universal
1
1000VA: 16.9 x 15.7 x 3.4" (430 x 400 x 85mm)
1500VA and 2000VA: 16.9 x 18.5 x 3.4" (430 x 470 x 85mm)
3000VA: 16.9 x 21.3 x 3.4" (430 x 540 x 85mm)
1000VA: 37 lbs (16.8kg)
1500VA: 46.2 lbs (21kg)
2000VA: 47.5 lbs (21.6kg)
3000VA: 66 lbs (30kg)
818275802683
Models | SKU: VLGXT500LVRT $1,043.85 $1,656.90 Save:$613.05 (37%) Ships from Manufacturer 4 Styles Available Usually ships within 1-2 Days | SKU: CYPR2200RT2U MFR: PR2200RT2U $1,091.95 In Stock | SKU: CYBOL1000L2U MFR: OL1000RTXL2U $985.95 Ships from Manufacturer Usually ships within 1-2 Days |
---|---|---|---|
Type | Uninteruptible Power Supply | Backup Power Battery | Uninteruptible Power Supply |
Cable Length | 10' | 10' | 10' |
Joules | - | 2430 | - |
Rack Units | 2U | 2U | 2U |
Intelligent and Efficient UPS for Protection of Your Mission-Critical Applications
The Vertiv Liebert GXT5 UPS is an online double conversion UPS solution which offers premium power outage protection and continuous power conditioning in a compact and flexible rack/tower form factor.
Scalable runtime options with matching external battery cabinets offer additional flexibility when extended uninterrupted power is required. Plus, the Liebert GXT5 provides battery health status and replacement date prediction for intelligent battery health management.
With market leading efficiency and unity power factor operation, the Liebert GXT5 will meet your critical application needs.
Leading UPS Technology
High output power factor = up to 1.0
Full-color graphic LCD with gravity sensing orientation
Individually controllable output power sockets
External battery cabinets with auto-detection
Battery health status and replacement date prediction
Remote management, update, and configuration capabilities
Optimized thermal management and variable speed fan
Efficient and Green Product
High efficiency in online mode
Energy Star 2.0 certified
Even higher efficiency (up to 98%) in Active ECO mode
Programmable outlets for power cycling hung equipment and optimum battery usage
Compliance with Restriction of Hazardous Substances (RoHS) directive and the Registration, Evaluation, Authorization and Restriction of Chemicals (REACH) regulation
Solutions Wide
Compact rack/tower design
Easy to install, configure and operate
Vertiv RDU101 network communications card with advanced features
Compatibility with environmental sensors
Integrated dry-contacts with selectable definition
Free Vertiv Power Insight management software
Serial port for out-of-band management with Avocent serial consoles
Automatic internal bypass and external maintenance bypass options
High power factor (0.9-1.0)
More usable power enables more connected loads saving space and costs.
Efficiency (up to 95%) in online mode
Energy Star Certified High energy efficiency saves on energy costs and reduces heat dissipation from the UPS.
Efficiency (up to 98%) in Active ECO mode
Superior protection with maximum efficiency.
Colored graphic LCD with gravity sensitive orientation
User-friendly interface provides insight to UPS status for easy installation, configuration and operation.
Compact rack/tower design
Space-saving UPS provides rack space optimization and flexible installation.
Battery cabinets with auto-detection
Be confident the UPS is set up correctly to report available runtime when used with external battery cabinets.