Review Summary
750VA/675W, 1100VA/990W, 1440VA/1350W
750VA: 115VAC
1100VA: 120VAC
1500VA: 125VAC
With battery operation: 0-150VAC
Without battery operation: 75-146VAC
3%
750VA: 135VAC
1100VA: 140VAC
1500VA: 146VAC
55-65 Hz (57-63 Hz Battery to Normal comeback)
750VA: 10A
1100VA: 13A
1500VA: 16A
ANSI C62.41, Category A, Level 3 1372 J
NEMA 5-15P, offset 90-degree type (3 m attached)
750VA: 115VAC ( +/-1.5 on battery before alarm) user selectable (120 VAC is factory default)
1100VA: 120VAC ( +/-1.5 on battery before alarm) user selectable (120 VAC is factory default)
1500VA: 125VAC ( +/-1.5 on battery before alarm) user selectable (120 VAC is factory default)
60 Hz +/-1%
750VA: Not controllable - 3x NEMA 5-15R
1100VA: Not controllable - 3x NEMA 5-15R
1500VA: Controllable - 3x NEMA 5-15R
Adjustable with User Setting 09 ST1: 4-6ms typical, 10ms max (default) ST2: 4-6ms Typical, 11ms max ST3: 8-10ms typical, 13ms max
Pure Sinewave
100%- alarm warning 110% - alarm warning and shutdown after 10 seconds 120%- alarm warning and immediate shutdown
Electronic (over current, short circuit w/ latching shutdown)
93%
32 Degree F-104 Degree F (0 Degree C-40 Degree C)
-5 Degree F - 122 Degree F (-15 Degree C-50 Degree C)
20% to 90% Non-condensing
0 - 9,942' (0 -3,000m) without derating Operating temperature reduced 9 Degree F (5 Degree C) for each additional 1,640' (500m) of altitude.
750VA: < 45dB
1100VA: < 45dB
1500VA: < 45dB@line mode, <55dB@battery mode
UL 1778, c-UL-us Listed
FCC Part 15, Class B
UL 497 B
ISTA Procedure 1A Certification
Valve-regulated lead-acid (VRLA) in compliance with UL 1989
6-8 hours to recover 90%
750VA: 12V x 9Ah
1100VA: 12V x 10Ah
1500VA: 12V x 9Ah
Required, included
Lead acid
Non-universal
1
750VA and 1100VA: 5.7 x 14.8 x 8.7" (145 x 376 x 220mm)
1440VA: 5.7 x 19.1 x 8.7" (145 x 484 x 220mm)
750VA: 24.7 lbs (11.2kg)
1100VA: 26 lbs (11.8kg)
1440VA: 40.1 lbs (18.2kg)
999560111991
Liebert PSI5 is a compact, Automatic Voltage Regulation (AVR) line-interactive UPS system designed especially for IT applications such as network closets and small data centers.
The Liebert PSI5 UPS supports advanced pure sine wave output on battery to safeguard critical IT equipment and business electronics. It also provides reliable power protection for servers, critical nodes, network workstations, large network peripherals, network routers, bridges, and other electronic equipment. With 3 different form-factors available, the Liebert PSI5 has been designed to ensure power continuity for a wide array of applications
Ideally suited for:
Servers
Network Closets
Safety and Security systems
Network Workstations
Large Network Peripherals
Storage
VolP
Media Closet Equipment
POS Systems
Mini Tower
Compact Mini Tower design for tower servers and/or applications with no available rack
Plug and play solution requiring no installation
Vertiv Intellislot SNMP/Webcards available for remote power management, and environmental sensor support
Reliable UPS protection to keep your network up and running
The Liebert PSI5 UPS features an innovative advanced line-interactive design incorporating buck/boost Automatic Voltage Regulation (AVR) technology.
This protects against utility voltage fluctuation by raising and lowering utility power to the level needed by the connected equipment. It also allows the UPS to prolong battery life by maximizing its time on utility power before going to battery.
With high efficiency and 0.9 power factor operation, the Liebert PSI5 will meet your critical application needs. You can rest assured that your business is protected with this Vertiv solution.
High Availability
0.9 Output Power Factor
More usable power enables more connected loads saving space and costs
Wider Input Voltage Window
Prolongs battery life by allowing the UPS to maximize the use of utility power before transferring to battery when input exceeds specified limits (76 to 146 VAC @120V)
Full Sequenced Battery Testing
The Liebert PSI5 UPS includes an automatic and manual self-diagnostic test feature. This provides a comprehensive analysis of the condition of the batteries within the UPS and will notify you when the internal batteries need to be replaced.
Advance Early Warning of UPS System Status
The Liebert PSI5 UPS offers multiple audible and visual alarms to immediately alert you to an input voltage fluctuation (buck/boost), output overload, low battery or replace battery condition.
Flexibility
Up to Seven Battery-Backed Outlets
Allows the Liebert PSI5 to be more flexible in accommodating additional equipment to be connected to the UPS via the receptacles
Configurable Input Voltage Window
Allows the UPS to be properly matched to the incoming utility power and adjusts its input window and transfer points to supply regulated power to connected loads within the selected range.
Programmable Outlet Group
Power cycle connected equipment and load shed on battery to extend run time.
Manageability
USB Communications
Power management functions provide monitoring of UPS status and manage the automatic orderly shutdown of the computer if a power outage ever exceeds the battery capacity of the UPS. Trellis Power Insight Shutdown Software is available at Vertiv.com
Remote Emergency Power Of
Allows the UPS to be remotely shut down during an emergency.
Optional Liebert MicroPod Output Distribution and Maintenance Bypass Module
When your computer system can't be without power, even for scheduled UPS maintenance, the Liebert MicroPod ensures continuous uptime. It allows you to manually transfer connected equipment to utility power permitting scheduled service or UPS replacement without the need to shut down connected equipment.
Features include:
2U height minimizes rack space requirements
Installs with plug-and-play ease