See Options
2 Year
$219.99
3 Year
$349.99
5 Year
$689.99
Need help? Ask our experts.
Review Summary
Accidents happen. Protect your favorite Adorama products and purchase a protection plan to stay covered from accidental damage, mechanical or electrical failures, and more.
If we can’t fix it, we’ll replace it at no additional cost.
Protect your product from drops, spills, and more.
Enjoy your gear without fear. We have you covered!
When regular use of your product over time results in mechanical or electrical failure.
We will never charge you a deductible after the purchase of a plan.
Our claims process is simple & easy and our customer service team is happy to help.
Adorama Protect powered by Extend is available for purchase to customers in the United States. Not available for international or U.S. territories purchases. Plans on open box items do not cover pre-existing damage.
Adorama Protect plans are available for ABS clients. If you have any questions or require assistanse, please call 800-223-2500
Browse our FAQ
This prevents possible acoustic reflections from the XL2 housing and ensures a high measurement accuracy in accordance with the standards IEC 61672 and ANSI S1.4
IEC 61672:2013, IEC 61672:2003, IEC 61260:2014, IEC 61260:2003, IEC 60651, IEC 60804, IEC 61183
SMPTE ST 202:2010, ISO 2969:2015
China: GB/T 3785:2010, GB/T 3241, GB 3096-2008, GB 50526, GB-T 4959
Germany: DIN 15905-5, DIN 45657:2014, DIN 45657:2005, DIN 45645-2
Japan: JIS C1509-1:2005, JIS C 1513 class 1, JIS C 1514 class 0
Switzerland: V-NISSG
UK: BS 4142:2014, BS 5969, BS 6698
US: ANSI S1.4:2014, ANSI S1.43, ANSI S1.11:2014, ANSI/ASA S12.60
WELL Buildings, LEED Green Building
FGI Facility Guidelines Institute
Frequency weighting: A, C, Z (simultaneous)
Time weighting: Fast, Slow (simultaneous)
Measurement bandwidth (-3dB): 4.4 Hz - 23.0 kHz
Level resolution: 0.1 dB
Internal noise: 1.3 microV A-Weighted Audio Recording
Default:
Recording of compressed wav-files (ADPCM - 4 bit, 24 kHz)
A new wav-file starts every 12 hours (max. wav-file size 512 MB)
Bandwidth: 2.0 Hz - 10.2 kHz
Audio files include meta data (scaling, time, ...) in Broadcast Wave Format BWF according to EBU TECH 3285
< 10 seconds
Minimum: 1 second
Maximum: 100 hours minus 1 second
SPL actual, Lmin, Lmax, Lpeak, Leq, Lp
Gliding LAeq and LCeq with selectable time window from one second to one hour (=running Lxeq or sliding Lxeq with x= A or C)
All measurement results simultaneously available
Correction value measurement wizard based on LAeq, LCeq and LCpeak
Noise exposure level LEX with post-processing
Logging all data or subsets in selectable intervals
Recording of voice notes
Monitoring of sound levels that exceed limits
Digital I/O interface for external peripherals control
Conforms with class 1 of IEC 61260:2014 and ANSI S1.11-2014
1/1 octave band display: 8 Hz - 16 kHz, sub ranges 8 Hz - 4 kHz or 31.5 Hz - 16 kHz displayed with A/Z broadband levels at one glance
1/3 octave band display: 6.3 Hz - 20 kHz, sub ranges 6.3 Hz - 8 kHz or 20 Hz - 20 kHz displayed with A/Z broadband levels at a glance
Level resolution: 0.1 dB
Measurement Units: Volt, dBu, dBV and dBSPL
Band pass filters (base 10) conform with class 1 of IEC 61260:2014 and ANSI S1.11-2014
Wide band levels simultaneously
Frequency weighting: X-Curve @ 500 seats in accordance with SMPTE ST 202:2010 and ISO 2969:2015
Capturing of a single reading into the internal memory for comparative measurements
Leq logging
Real-time FFT with actual level, Leq, Lmin, Lmax
Level resolution: 0.1 dB
Frequency Band Ranges: 7 Hz - 215 Hz, 58 Hz - 1.72 kHz, 484 Hz - 20.5 kHz with 143 frequency bins shown on display
Measurement Units: Volt, dBu, dBV and dBSPL
Conforms with ISO 3382 and ASTM E2235
1/1 octave bands results from 63 Hz - 8 kHz, based on T20 and T30
Range: 10ms - 30seconds
Minimum reverberation time (typical):
< 100 Hz: 0.3 second
100 - 200 Hz: 0.2 second
> 200 Hz: 0.1 second
Measurement based Schroeder-method
Test signal: Impulse source or interrupted pink noise generated by the MR-PRO, MR2 or the included NTi Audio Test CD/USB Flash Drive
Checks polarity of speakers and line signals
Positive/Negative detection of wideband and individual 1/1 octave bands through internal microphone or XLR/RCA connector
Test signal: NTi Audio polarity test signal generated by the MR-PRO, MR2 or the included NTi Audio Test CD / USB Flash Drive
Propagation delay between electrical reference signal and acoustic signal using the internal microphone
Range: 0 ms - 1 second (0m to 344m)
Resolution: 0.1 ms
Test signal: NTi Audio delay test signal generated by the MR-PRO, MR2 or the included NTi Audio Test CD / USB Flash Drive
Noise Rating NR according to ISO/R 1996-1971
Noise Criteria NC in accordance with ANSI S12.2-2019 and -1995
Room Noise Criteria RNC in accordance with ANSI S12.2-2019
Room Criteria RC in accordance with ANSI S12.2-1995
Preferred Noise Criteria in accordance with ASA 1971
IEC 61672, IEC 60651, IEC 60804
DIN EN 60065, VDE 0860, IEC 468-4
True RMS detection in V, dBu, dBV, dBSPL
Power measurement in Watt or dBm with flexible load setting from 1.0 to 9999 Ohm
Range XLR/RCA input: 2 microV - 25 V (-112 dBu to +30 dBu)
Accuracy: +/- 0.5 % @ 1 kHz
Flatness: +/- 0.1 dB @ 12 Hz to 21.3 kHz
Bandwidth (-3 dB): 5 Hz to 23.6 kHz
Resolution: 3 digits (dB scale), 5 digits (linear scale) or 6 digits (x1 scale)
Following measurement functions offer audio spectrum in Volt, dBu and dBV
Sound Level Meter
FFT
Range: 9 Hz to 21.3 kHz
Resolution: 6 digits
Accuracy: < +/- 0.003%
Total Harmonic Distortion + Noise:
Range: -100 dB to 0 dB (0.001% to 100%)
Minimum level: > -90 dBu
Fundamental frequency range: 10 Hz to 21.3 kHz
Measurement bandwidth: 2 Hz to 23.6 kHz
Resolution: 3 digits (dB scale) or 4 digits (linear scale)
Residual THD+N @ XLR/RCA input: < 2 microV
Auto ranging, auto scaling
Frequency weighting: A, C, Z
Highpass: 100Hz, 400 Hz, 19 kHz
Bandpass: 22.4 Hz - 22.4 kHz in accordance with IEC468-4
50mm Wind Screen: +0,12 dB
90mm Wind Screen: +0,19 dB
WP30/WP61 Wind Screen 90mm: +0,19 dB
Recommended calibration interval: one year
Microphone calibration with external calibrator supported
1x (Single-channel)
Real time measurement in:
Acceleration: m/sq. s, g, in/sq. s, dB
Velocity: m/s, in/s, dB
Displacement: m, in, dB
Peak particle velocity PPV: mm/s, in/s
Levels: RMS, Peak, Peak-Peak
Broadband level:
Frequency range: 0.8 Hz - 2.5 kHz
Spectral:
1/1 octave band display: 1 Hz - 2.0 kHz sub ranges 1 Hz - 500 Hz or 4 Hz - 2 kHz
1/3 octave band display: 0.8 Hz - 2.5 kHz sub ranges 0.8 Hz - 1.0 kHz, 2.5 Hz - 2.5 kHz
Broadband level measured with bandwidth (- 3dB): 0.7 Hz - 23.6 kHz
Display according to DIN 45669-1:2010:
Unweighted velocity v(t)
Maximum absolute velocity
Averaging duration
Measurement duration
Flat (no filter) Bandwidth (- 3dB): 0.7 Hz - 23.6 kHz
10 - 1000 Hz according to ISO 2954 with decay rate = 18 dB / octave
1 - 80 Hz, 1 - 315 Hz acc. to DIN 45669-1:2010 with decay rate = 12 dB / octave
Default:
Recording of compressed wav-files (ADPCM - 4 bit, 24 kHz)
a new wav-file starts every 12 hours (max. wav-file size 512 MB)
Bandwidth: 2.0 Hz - 10.2 kHz
Frequency range: 1 Hz - 1.69 kHz
353 m/sq. s, 36 g @ 20 mV/(m/sq. s) with ICP Adapter ASD
With ICP Adapter ASD:
17 microV @ 0.7 Hz to 23.0 kHz
14 microV @ 1 Hz to 315 Hz
14 microV @ 1 Hz to 80 Hz
Mid
XLR balanced:
Input impedance = 200 kOhm
Phantom power: +48 VDC switchable with maximum 10 mA supply current in accordance with IEC 61938
Automated sensor detection for NTi Audio's ASD measurement microphones and pre-amplifier MA220
RCA unbalanced with input impedance >30 kOhm
Built-in Condenser microphone for polarity testing, delay measurements and voice note recording
Built-in speaker
Headphone connector:
3.5 mm Minijack
mono monitor wired to both channels of stereo jack
Linear output signal over a measurement range of 57 dB in SLMeter measurement function
USB mini connector for data transfer to PC, XL2 Projector PRO and/or charging of Li-Po battery
Connection interface to accessories:
XL2 Input Keypad
Limit Light
Stack Light
Digital I/O Adapter PCB
24 bit linear PCM audio signal output (prepared for later firmware extension)
SD Card included (8GB), removable, storing measurement data in ASCII format, screen shots, voice notes and wav-files
Data logging every second offers following noise monitoring periods:
Logging default noise levels: > 2 years
Additional logging of 1/3 octave data: > 6 month
Additional compressed audio recording: > 1 week
Additional linear audio recording: > 15 hours
Rechargeable Li-Po battery included
Type 3.7 V / 2260 mAh
Typical battery lifetime > 4 hours
Range: 3.3 - 4.5 VDC
Volume energy density = 339 Wh/l
Dry cell batteries type AA, 4x 1.5 V
Range: 3.7 - 6.0 VDC
Linear external power supply 9 VDC
Range: 7.5 - 20.0 VDC @ minimum 6 Watt
Charges Li-Po battery during operation
USB-Power Supply
for short-term operation < 1 day
charging power is equal or less than power consumption
External battery pack
22 Ah battery pack: 4 days
44 Ah battery pack: 8 days
Default:
Real-time clock with lithium backup battery
Typical life backup battery: 8 years
Return instrument for battery replacement
Drift < 1.7 seconds per 24 hours
Tripod or microphone stand mount 1/4"
Wire stand mounted on rear side
Display: 160 x 160 pixels gray scale with LED backlight
14 Degree to 122 Degree F (-10 Degree C to 50 Degree C)
5% to 90% RH, non-condensing
65 kPa to 108 kPa
Classification Group X
CE compliant:
EN 61326-1 Class B, EN 55011 class B, EN 61000-4-2 to -6 & -11
IP51
For applications in explosive atmospheres within zone 2 in accordance with IEC 60079
Conforms to 2014/34/EU
Required, included
Lithium ion
Non-universal
1
7.1 x 3.5 x 1.8" (180 x 90 x 45mm)
1.05 lbs (480g) (Including built-in Li-Po battery)
Balanced XLR, unbalanced RCA phantom power resistant
DC power supply, USB XLR for cable test
Sine, Polarity Test Signal, Delay Test Signal
White Noise (crest factor, PAR = 3.05 (9.7 dB), 5 Hz - 22 kHz)
Pink Noise (crest factor, PAR = 4.5 (13.1 dB), 5 Hz - 22 kHz)
Gated Pink Noise (1 - 9 seconds), Wave File playback
Fast Pink Noise 1s (PAR = 12.5 dB)
Fast Pink Noise 4s (PAR = 13.1 dB)
NTi Audio STIPA
Sampling frequency: 48 kHz
Resolution: 16 Bit, Mono / Stereo
Output level: 0 dBFS = 18 dBu (sine) acc. to EBU R68
Range: 10 Hz to 20 kHz
Increment: in 1 digit steps
Accuracy: 0.01%
Frequency range: freely selectable
Increment: 1/1, 1/3, 1/6, 1/12 octave
Sweep speed: selectable 0.5 to 5 seconds
Frequency range: freely selectable
Increment: Linear / Logarithmic
Chirp speed: 1 to 99 seconds per cycle
Units: dBu, dBV, V, dBFS, %
Increment: in 1 digit steps (e.g. 0.1 dBu)
Sine, Sweep, Chirp: -80 dBu to +18 dBu
White Noise: -80 dBu to +10 dBu
Pink Noise: -80 dBu to +8 dBu
Polarity, Delay Test: -80 dBu to +16 dBu
+/-0.2 dB @ 10 Hz to 12 kHz
-0.1 dB / +0.3 dB @ 12 kHz to 20 kHz
+/-0.2 dB
22 Hz to 22 kHz, average, @ 1 kHz, typical
-96 dB (0.0016%) @ 18 dBu, Noise floor typ. 15 micro V
12.5 Ohm balanced, Imax = 10 mA
Method:
Absolute value Z
Measurement range:
4 Ohm to 50 kOhm (pin 2-3)
2 Ohm to 25 kOhm (pin 1-2 or 1-3)
@ f = 30 Hz to 10 kHz (Sine)
@ Level from -20 to +18 dBu
Accuracy:
+/-10% or +/-2Ohm (whatever is higher)
Reference voltage: 25 V, 35 V, 50 V, 70.7 V, 100 V, 140 V, 200 V
Measurement range: 0 to 54 V
Accuracy: +/-3 % or +/-0.5 V
Firmware update
Mass Storage Device
512 MB for storing wave files and configurations
>= 99% @ 1 kHz for output levels above -20 dBu
Graphical, with back light
10, 30, 60 minutes or Off
3x AA Alkaline dry cells or rechargeable equivalents (not included)
0 dBu, no load, typical: 8 hours
32 to 113 Degree F (0 to 45 Degree C)
< 90% relative humidity, non-condensing
IP51
For applications in explosive atmospheres within zone 2 in accordance with IEC 60079; conforms to 2014/34/EU
5.98 x 3.19 x 1.69" (152 x 81 x 43mm) (Including protective shock jacket)
11 oz (310g) (With Batteries)
Class 2 (according to IEC 61672 and ANSI S1.4)
1/4" fixed mounted
No
+1/-5 dB @ 5 Hz - 20 Hz
+/-1.5 dB @ 20 Hz - 4 kHz
+/-3 dB @ 4 kHz - 20 kHz
10 Hz - 30 kHz
-36 dBV/Pa +/-3 dB (16 mV/Pa)
32 dB(A) SPL @ 16 mV/Pa
140 dB SPL (@ distortion factor 3%, 1 kHz)
< +/-0.03 dB / Degree C
32 Degree F to 104 Degree F (0 Degree C to 40 Degree C)
-0.04 dB / kPa
< +/-0.4 dB
5% to 90% RH, non-condensing
48 VDC phantom power
1.4 mA idle, 5 mA @ clip level
NTi Audio ASD according to IEEE P1451.4 V1.0, Class 2, Template 27
100 Ohm symmetrical
Balanced 3-pin XLR
IP 51
Housing: 0.8" (20.5mm)
Neck: 0.3 "(7.8mm)
Recess for calibrator: 0.27" (7mm)
5.9" (150mm)
2.93 oz (83g)
- XL2 Audio and Acoustic Analyzer -
Switch on. Measure. Analyze.
Sound Level Meter
Spectrum Analyzer
STIPA Analyzer
Audio Analyzer
Vibration Meter
The hand-held XL2 Analyzer is a powerful Sound Level Meter, a professional Acoustic Analyzer, a precision Audio Analyzer and a comprehensive Vibration Meter in one instrument. Easy operation and countless applications distinguish this quality Swiss product.
The XL2 as a Sound Level Meter
Numerous measurement variations are simultaneously available. Actual level (live), Lmin, Lmax, Leq and Lpeak may be measured in combination with frequency weighting A, C or Z and time weightings fast, slow and impulse. All results are simultaneously available and may be stored automatically for later documentation.
Customers may log all acquired level information onto a removable SD card. Additionally the XL2 offers wav-file recording for a complete documentation of the measured sound pressure levels. Voice notes may also be added to each measurement.
The XL2 as a Real Time Analyzer RTA
The RTA perfectly suits tasks such as optimization of sound systems and rooms. The XL2 measures and logs wideband values and the real time spectrum in 1/1 or 1/3 octave-band resolution according to IEC 61260 class 0. The sound level meter results of the wideband and RTA spectrum are simultaneously available.
Features
1/3 octave, 1/1 octave
Frequency weighting: A, C, Z (=flat)
Time weighting: Fast, slow
Performance & Functional
Switch on - Good to go
Get the job done, on time! The instrument is ready to measure literally seconds after you press the power button. The intuitive navigation and flexible user interface assist in simplifying every task. The XL2 provides an extensive range of measurement functions.
Ready for any Challenge
The XL2 is developed according to user needs, and provides reliable measurement solutions for sound system installations, noise control, architectural acoustics, evacuation systems, live events, quality inspection and occupational health and safety. Discover an instrument you can trust for specialist applications.
5 reasons why the XL2 is the right choice for you
The XL2 Acoustic Analyzer offers numerous measurement functions relevant to your application in one instrument. Thanks to the intuitive operation, you can quickly and easily switch between the different measuring functions.
The intuitive user interface makes operation child's play without having to study the user manual
Rugged and ready for tough environments
All measurement results are stored on a removable SD card as TXT files, which can be further processed externally with a PC or MAC
The XL2 has many expandable measurement functions. So, if you have other acoustic or audio measurement tasks, it's likely that the XL2 can help you.
Together with the Type Approval Option, the XL2 is an approved Sound Level Meter
Incomparable Value
The XL2 Audio and Acoustic Analyzer provides top-class performance with excellent value for money. You will receive an instrument exactly tailored to your needs for less than you expect.
Data Analysis and Reporting
The XL2 stores all data onto the SD card for direct transfer to the computer. Data reports and log files are stored in plain text format, which can be opened with any text editor (Notepad, Wordpad, etc). The data is tab-delimited, so dropping the .txt file into a spreadsheet application will conveniently show the results in columns. The sound level meter may additionally record the audio data as a WAV-file.
A series of free MS Excel application templates provide a convenient way to view the measurement results of specific tasks and create simple reports.
Free Reporting Tools
Basic Live Sound and Noise Monitoring Reporting
Noise Exposure
Speech Intelligibility Reporting
- Minirator MR-PRO -
Compact. Portable. Indispensable.
Analog Audio Generator
Impedance Meter
Cable Tester
The Minirator MR-PRO provides a full set of analog audio signals including sine wave, pink noise, white noise, delay test signal, polarity test signal, stepped sweep and continuous sine sweep. Further, a set of wav-files, useful for system optimization, is stored in the internal flash memory. Add your own personal favorites to this set.
Besides the broad range of generated audio signals, the Minirator MR-PRO monitors the signal balance, phantom power and impedance of the connected load. An integrated XLR cable tester simplifies trouble shooting tasks.
Test Signals
Sine
Minirator generates pure sine waveforms at user-selectable frequencies and amplitudes. The frequency steps interval can be set to as low as 0.1Hz.
Selectable frequencies from 10 Hz to 20 kHz
Level range from -80 to +18 dBu
Sweep
The start/stop frequency, step time and a step resolution as fine as 1/12th octave can be adjusted. Audio analyzers automatically trigger to this signal and record the frequency response of a device under test.
Chirp
The chirp signal is a logarithmic or linear gliding sine sweep signal with continuous frequency increase over time. Typical applications are recording of frequency responses, impulse response measurements and acoustic assessment of rooms.
Delay Test Signal
This is the designated reference signal to measure the acoustic propagation delay time from speaker to speaker in e.g. churches or auditoriums. It suits the accurate setup of delay line arrangements, thus the directionality of the signal source will be optimized. Testing is carried out in combination with a Sound Level Meter.
Pink & White Noise
Pink or white noise is synthesized with high spectral density, normal amplitude distribution and with infinite cycle duration. The Minirator also generates gated pink noise (on/off cycle 1 - 9 seconds) for convenient Reverberation Time measurements with the Sound Level Meter.
Polarity
Test signal for measuring the polarity of speakers and audio signals. The saw-tooth waveform is an ideal stimulus with only moderate stress to speakers.
User Wav-Files
The Minirator MR-PRO offers a range of additional factory test files, e.g. for speech intelligibility verification. You may store additional user test signals as uncompressed wav-files in the MR-PRO memory. The selected file is seamlessly looped. Wav-file exchange is simplified via the USB port. Pre-installed - STIPA, Voice, Music.
Measurement Functions in Generator Mode
Providing a detailed view of the connected load for rapid fault finding.
XLR Signal Balance
Load Impedance
Phantom Power Voltage
Cable Test
The MR-PRO verifies the correct XLR cable wiring, detecting all common XLR wiring faults with a precise description, such as "2-3 Crossed" or "Pin 2 open". Additionally an Cable Test Plug may be used for single ended installations.
Impedance and Power Test
MR-PRO measures the impedance, phase and power rating of distributed speaker systems at selectable frequencies.
Impedance and Phase
Apparent Power and Phase
Store Preset Configurations
Up to 10 complete instrument configurations can be stored in the internal flash memory and reloaded for repetitive tasks. The saved settings may also be transferred to other MR-PRO instruments.
Compensated Output Stage
The output level corresponds over a wide range of loads to the set output voltage compensating the output impedance of the generator. Possible maximum limits when reaching the output current limit are clearly indicated.
- M4262 Measurement Microphone -
The measurement microphones are optimized for a flat, free-field response in the frequency range 10 Hz - 30 kHz. The microphone is omni-directional and 48V phantom powered. The Sound Level Meter microphones include an electronic data sheet. The Automated Sensor Detection (ASD) of the Analyzer automatically reads this data sheet, and recognizes the microphone model, sensitivity and calibration data. This ensures accurate measurement results.
Measurement Microphones for the XL2 / XL3 Sound Level Meter
The microphones are 48 V phantom powered and include an electronic data sheet. The Automated Sensor Detection (ASD) of the Analyzer automatically reads this data, i.e. the microphone model and calibration data. This promotes faster setup and ensures accurate measurements.
The microphone bodies contain the preamplifier. They combine high dynamic range and wide frequency range with low noise. These measurement microphones connect via the ASD Cable to the Sound Level Meter e.g. for measurements at remote locations or to reduce acoustic reflections.