See Options
Need help? Ask our experts.
Review Summary
1000VA/1000W, 1500VA/1350W, 2000VA/1800W, 3000VA/2700W
2U Rack/Tower
1000VA and 1500VA: NEMA 5-15P
2000VA: NEMA L5-20P
3000VA: NEMA L5-30P
1000VA, 2000VA and 3000VA: 10' (3m) Attached
2000VA: 10' (3m) Attached L5-20 To 5-20P Adapter
1000VA: 6x NEMA 5-15R
1500VA: 6x NEMA 5-15R
2000VA: 1x NEMA L5-20R, 6x NEMA 5-15/20R
3000VA: 1x NEMA L5-30R, 6x NEMA 5-15/20R
1000VA and 1500VA: 4x NEMA 5-15R
2000VA and 3000VA: 4x NEMA 5-15/20R
120VAC Default; 100/110/115/120V/125VAC (User-Configurable)
Nominal (Full Load): 102 - 150 VAC; Maximum: 60 - 150 VAC
40-70Hz
ANSI C62.41, Category B
0 ms
Pure Sine Wave
32 Degree F to 104 Degree F (0 Degree C to 40 Degree C) (10% Derating at 122 Degree F (50 Degree C))
-4 Degree F to 140 Degree F (-20 Degree C to 60 Degree C)
0% - 95%, non-condensing
0' to 10000' (0m to 3048m) w/o Derating (15% Derating at 4000m)
< 48 dB
UL 1642 (Li-Ion Battery Cells), UL 1973 (Li-Ion Battery Pack w/UPS), UL 1778, CSA 22.2 No. 107.3
UL 1778, c-UL, NOM, FCC Part 15, Class A
RoHS2 / REACH / WEEE
IEC 61000-4-5, ANSI C62.41, Category B
ISTA Procedure 2A
Lithium-Ion (LiFePO4)
< 2 hrs to 90%
1000VA:
Full-Load: 13 min
Half-Load: 28 min
1500VA:
Full-Load: 14 min
Half-Load: 28 min
2000VA:
Full-Load: 10.5 min
Half-Load: 22.5 min
3000VA:
Full-Load: 6.5 min
Half-Load: 15 min
Required, Included
Lithium ion
Non-universal
1
1000VA: 16.9 x 17.3 x 3.4" (430 x 446 x 85mm)
1500VA and 2000VA: 16.9 x 18.7 x 3.4" (430 x 476 x 85mm)
3000VA: 16.9 x 21.5 x 3.4" (430 x 546 x 85mm)
1000VA: 37.5 lbs (17kg)
1500VA and 2000VA: 39.7 lbs (18kg)
3000VA: 48.5 lbs (22kg)
DC Input: 7 to 12 VDC
Power Consumption: 3.6 W maximum
32 Degree F to 104 Degree F (0 Degree C to 40 Degree C), 10% to 90% RH (Non-condensing)
-4 Degree F to 140 Degree F (-20 Degree C to 60 Degree C)
Ethernet Communication
RJ-45
10/100 Mb/s Ethernet Connector: 328' (100m) Standard Category 5E Cable
RJ-45 - One-Wire Connector: 65.6' (20m) Liebert Integrated One-Wire Sensor Cable or 2m Cat 5E to Modular 1-Wire
2.97 x 5.2 x 1.45" (75.5 x 15 x 37mm)
7 oz (198.44g)
767041037975
Models | $2,047.50 $3,250.00 Save:$1,202.50 (37%) Temporarily On Backorder 4 Styles Available Although this item is temporarily on Backorder, you can order it now and it will ship as soon as it arrives. Your card will only be charged once item is shipped. | SKU: CYOL22RTXL2N MFR: OL2200RTXL2UN $1,986.95 Ships from Manufacturer Usually ships within 1-2 Days | SKU: TLSM2200RM2U MFR: SMART2200RM2U $1,107.90 $1,924.42 Save:$816.52 (42%) In Stock |
---|---|---|---|
Type | Uninteruptible Power Supply | Backup Power Battery | Uninteruptible Power Supply |
Cable Length | 10' | 10' | 10' |
Joules | - | 1335 | 570 |
Rack Units | 2U | 2U | 2U |
- GXT5LI 120V Lithium-Ion Online Rack/Tower UPS -
The Vertiv Liebert GXT5 Lithium-Ion UPS provides the highest level of power protection for your business critical IT applications.
High Performance Online Power Protection
The GXT5 Lithium-Ion double conversion online UPS provides both the highest level of power conditioning and battery backup for business critical IT equipment such as business network gear and servers ensuring your mission-critical applications are protected in the event of an unanticipated loss of power or an unprecedented power surge.
The GXT5 Lithium-Ion UPS protects against the widest range of power fluctuations and automatically switches to battery backup when power loss is detected. With a 0.9 or better output power factor (PF) and no transfer time to operation on battery, you can ensure your most critical assets are protected.
Protects Against
Outages
Sags
Surges
Spikes
Transient
Under-Voltage
Over-Voltage
The rack/tower convertible design of the Vertiv Liebert GXT5 Lithium-Ion UPS makes it ideal for edge or distributed IT applications where floor space is at a premium. It is a true low-maintenance, set-it and forget-it solution ideal for remote locations with limited onsite technical resources.
1000VA, 1500VA, 2000VA, & 3000VA UPSs in a rack/tower convertible form factor
Hot-swappable, user-replaceable batteries increase the useable life of the UPS by allowing you to easily replace the batteries without disrupting power to connected equipment
Internal batteries offer industry-leading runtime (up to 14 minutes at full load) to protect critical equipment during an unexpected power loss
Lithium-Ion battery technology offers better performance in high temperature environments, supports up to 10 times more discharge cycles, and delivers faster recharge times compared to VRLA batteries
High Performance
0.9 (or Better) Output Power Factor (PF)
Provides more useable power enabling you to connect more equipment saving you money and space.
Increased Runtime
Internal batteries offer up to 14 minutes of runtime at full load.
Programmable Outlet Group
Extend run time when on battery power by power-cycling connected equipment and shedding less critical loads.
Battery Backed Outlets
Up to 7 battery backed outlets ensuring critical equipment is protected.
Advanced Warning Status
Receive early audible and visual alarms warning you of system status to alert you to an input voltage, output overload, low battery, or battery replacement condition.
Wide Input Voltage Range
Prolong battery life by allowing the UPS to maximize the use of the utility power before transferring to battery.
Superior Battery Technology
Fewer Battery Replacements
Lithium-Ion batteries require fewer battery replacements and last on average up to 3 times as long as traditional VRLA batteries reducing maintenance, labor, and replacement costs (lower TCO).
More Discharge Cycles
Lithium-Ion batteries deliver up to 10 times more charge / discharge cycles than VRLA batteries.
Fast Recharge
Lithium-Ion batteries recharge twice as fast as traditional VRLA batteries getting you back to 90% in as little as 2 hours.
Hot-Swappable, User-Replaceable Batteries
Increase product life and reliability with batteries that can be easily replaced without disrupting power to connected equipment.
Safe and Reliable
Safest Lithium-Ion (LiFePO4) battery chemistry and integrated battery management system (BMS) ensure safe and reliable operation.
Environmentally Friendly
Significantly reduce battery disposal and recycling with lower replacement rates.
Enhanced Manageability
LCD Display
User-friendly full-color LCD interface with gravity sensing orientation simplified installation and configuration while also providing instant at-a-glance status and insights.
Free Power Management Software:
Vertiv Power Insight - Add the Liebert RDU101 card for web/SNMP manageability
Vertiv Power Assist - Monitor UPS conditions through a local USB connection
Vertiv Intelligence Director - Together with Vertiv Geist rPDU one single IP Address to monitor and manage up to 50 devices
Remote Monitoring and Management
Add Liebert IntelliSlot RDU101 communication card to enable remote monitoring / management (web based, SNMP, BACnet, MODBUS and relay contacts) and environmental monitoring via external sensors.
Remote Emergency Power Off
Remotely shutdown the UPS during an emergency.
High power factor (0.9-1.0)
More usable power enables more connected loads saving space and costs.
Efficiency (up to 95%) in online mode
Energy Star 2.0 certification. Higher efficiency means an optimized energy management and lower heat dissipation, for energy savings and improved reliability.
Efficiency (up to 98%) in Active ECO mode
Superior protection with maximum efficiency.
Colored graphic LCD with gravity sensitive orientation
User-friendly interface provides insight to UPS status for easy installation, configuration and operation.
Compact rack/tower design
Space-saving UPS provides rack space optimization and flexible installation.
Battery cabinets with auto-detection
Be confident the UPS is set up correctly to report available runtime when used with external battery cabinets.
- RDU101 Communications Card -
The Liebert Intellislot RDU101 card enables communication between Vertiv products such as Trellis Enterprise, Trellis Power Insight and LIFE Services. It provides web access, data via SNMP and Modbus TCP for Vertiv equipment. Environmental sensor data access is provided via web and SNMP
How It Works
The RDU101 employs Ethernet networks to monitor and manage a wide range of operating parameters, alarms and notifications.
Solving Problems
Managing disparate systems within the data center can be challenging. With responsibilities to know the conditions of your facility at all times, keeping track of all that data may require accessing multiple systems or even performing manual, time consuming data tracking. Being able to collect data from your systems is key to effectively managing the data center. The RDU101 provides remote centralized monitoring connectivity to building management systems (BMS) that use SNMP.
Adding Value
Not only does the RDU101 improve efficiency by providing a one-to-one view of the connected system, it also provides a convenient way to configure and update devices via HTTP APIs. Save time on initial deployments and improve ongoing maintenance through the mass configuration capabilities of the RDU101.
Keep Data Secure
The RDU101 keeps data secure. Basic security is provided via HTTPS web connectivity and SNMP v3. Centralized access and authorization management provides an additional layer of security via remote authentication protocols - RADIUS, TACACS+, LDAP/AD and Kerberos.
Features
Provides web access to the installed devices via popular web browsers-Microsoft Internet Explorer, Mozilla Firefox, Google Chrome and Safari
Provides alarm notifications via email and text messaging
Supports environmental monitoring via Liebert SN Sensors for temperature, humidity, leak detection, doors and contact closures
Supports third-party protocols for building and network management applications for status and alarms via SNMP and Modbus TCP
Enables Vertiv software tools and services, including Trellis Enterprise, Trellis Power Insight and LIFE Services
Supports high-speed file transfer to managed devices for firmware and configuration updates
HTTPS messages and web access encryption with installable customer provided certificates
Options for SNMP v3 authentication support (none, MD5 or SHA), privacy support (none, DES or AES) and Traps